Industrial Network Security
Zones and conduits, segmentation, firewalls, remote access, hardening and the IEC 62443 approach.
On this page
- Why control networks need their own security
- Threats and how attacks happen
- Defense in depth
- Zones, conduits and the Purdue model
- Segmentation and firewall rules
- Secure remote access
- Hardening devices
- Passwords and accounts
- Security of each protocol
- Wireless, USB and removable media
- Monitoring, logging and backup
- IEC 62443 in practice
- When something goes wrong
- A machine-builder checklist
- FAQ
Why control networks need their own security
Office IT protects data: confidentiality comes first. A control network protects a process: availability and safety come first, then integrity, and confidentiality last. An office server can be rebooted on a Sunday; a furnace controller or a water pump cannot. Industrial devices also live for 20 years, are patched rarely, and often speak protocols (Modbus, DF1, older S7) with no security at all. The result is that control networks need extra care, a different order of priorities and different tools.
| Office IT | Control networks (OT) | |
|---|---|---|
| First priority | Confidentiality | Availability and safety |
| Patching | Monthly, automatic | Rare, planned, tested, during shutdowns |
| Lifetime of equipment | 3 to 5 years | 15 to 30 years |
| Protocols | TLS, HTTPS, modern authentication | Often plain Modbus, EtherNet/IP, S7, with no encryption |
| Downtime | Tolerated | Costly or dangerous |
| Real-time needs | Mostly none | Milliseconds matter; a scan can break a process |
| Typical error | Data leak | Spoiled batch, equipment damage, injury |
Threats and how attacks happen
Most attacks on industrial systems are not exotic. They use a few common routes, mostly open doors that were left unlocked.
| Route | How it happens | What stops it |
|---|---|---|
| Internet-exposed devices | A PLC, HMI or router with port 502, 44818, 102 or 3389 forwarded to the internet, found by scanners within hours | No direct internet exposure; VPN with multi-factor authentication |
| Phishing and the office network | Malware arrives by email on an office PC and spreads to the control network through a shared link | Segmentation; a DMZ; no direct office-to-PLC path |
| Default and weak passwords | Vendor default accounts, shared passwords written on the panel | Unique, strong passwords; disable defaults |
| Remote access shortcuts | A cellular router, a vendor’s remote tool or a forgotten TeamViewer | One controlled, logged remote-access path |
| Infected laptops and USB sticks | A contractor’s laptop or a thumb drive connected to the machine network | Clean-laptop policy; port control; scan stations |
| Unpatched known vulnerabilities | A published flaw in a controller or a Windows PC | Patch plan; virtual patching with a firewall |
| Insiders and mistakes | A wrong download, a wrong IP, a forgotten force | Access control, change control, backups |
| Supply chain | Compromised software or a vendor’s remote-support account | Vendor access rules; verify updates |
| Protocol weaknesses | Anyone on the network can read and write Modbus or CIP without authentication | Segmentation, allow lists, secure protocol variants |
Defense in depth
No single measure is enough. Defense in depth stacks several, so that one failure does not give the attacker the whole plant: policy and people, the perimeter, the network, the devices, the applications and the data.
| Layer | Measures |
|---|---|
| Policy and people | Written rules, training, who may connect what, vendor access procedures, an incident plan |
| Physical | Locked panels and rooms, cabinet door switches, disabled unused ports, port locks |
| Perimeter | Firewalls between plant, DMZ and enterprise; no direct internet |
| Network | Segmentation, VLANs, access control lists, managed switches, port security |
| Devices | Hardening, passwords, disabled services, firmware updates, program protection |
| Applications and data | Role-based access, signed projects, change control, backups |
| Monitoring | Logs, passive network monitoring, alerts |
Zones, conduits and the Purdue model
The Purdue model arranges a plant in levels from the process (level 0) to the enterprise (levels 4 and 5), and IEC 62443 turns that into zones (groups of assets with the same security needs) joined by conduits (the controlled communication paths between zones). The aim is that traffic crosses a zone boundary only where a rule allows it, and the enterprise reaches the plant only through a DMZ.
| Level | What lives there | Boundary rule |
|---|---|---|
| 5 and 4: enterprise | ERP, email, internet access | No direct path into the plant |
| 3.5: DMZ | Historian mirror, patch and antivirus servers, remote-access jump host | Both sides connect to it; neither connects through it directly |
| 3: site operations | MES, historian, engineering workstations | Only the services that supervisory systems need |
| 2: supervisory | SCADA, HMI servers | Allow the protocols to the PLCs (and no more) |
| 1: control | PLCs, drives, remote I/O | Only from the supervisory and engineering addresses that need them |
| 0: process | Sensors, actuators, safety devices | Safety systems on separate networks or fully independent |
Segmentation and firewall rules
The simplest strong measure is to divide the network into small zones and write down who may talk to whom. A firewall (or a managed switch with access lists) between zones then allows exactly that, and nothing else: a “default deny” policy.
| # | From | To | Protocol and port | Action | Reason |
|---|---|---|---|---|---|
| 1 | SCADA 10.20.30.10 | PLC 192.168.10.10 | EtherNet/IP: TCP 44818, UDP 2222 | Allow | Tag reads and writes |
| 2 | Historian 10.20.30.20 | PLC 192.168.10.10 | Modbus TCP: TCP 502 (read functions only if the firewall can inspect) | Allow | Data collection |
| 3 | Engineering PC 10.20.40.5 | PLC 192.168.10.10 | TCP 44818, 102 or the vendor’s port | Allow, logged | Programming and diagnostics |
| 4 | PLC 192.168.10.10 | NTP server 10.20.30.1 | UDP 123 | Allow | Time |
| 5 | Machine network | Internet | Any | Deny | No direct internet from the machine |
| 6 | Enterprise network | Machine network | Any | Deny | Only through the DMZ |
| 7 | Any | Any | Any | Deny and log | Default deny |
- Allow lists, not block lists. List what is needed; everything else is denied.
- Rules by address and port, not “any”.
- Log denied traffic. A blocked connection attempt is often the first sign of a problem or a forgotten dependency.
- Review the rules. A firewall with 300 rules nobody understands is a risk; remove the old ones.
- Industrial firewalls (deep packet inspection of Modbus, CIP, S7) can allow only certain function codes or tags and block writes from a read-only client.
- Test before enforcing. Run in log-only mode first and watch the real traffic, so that the rules do not stop the machine.
- Unidirectional gateways (data diodes) allow data out of a critical network with no path back: used in the most sensitive plants.
Secure remote access
| Practice | Why |
|---|---|
| One approved path | Every other route (cellular routers, vendor tools) is a hole |
| Multi-factor authentication | A stolen password alone is not enough |
| Individual accounts, not shared ones | You can see who did what, and remove one person at a time |
| A jump host in the DMZ | Remote users never reach the machine network directly; the jump host is monitored and hardened |
| Time-limited access, approved for each job | Access exists only while it is needed |
| Allow only the ports and addresses the job needs | Limits what a compromised remote PC can reach |
| Session recording and logs | Evidence and accountability |
| Vendor access agreements | Rules for outside engineers, including their laptops |
| Never expose a PLC or HMI port to the internet | Scanners find open Modbus, EtherNet/IP and S7 ports within hours |
Hardening devices
| Step | Detail |
|---|---|
| Change every default password | On PLCs, HMIs, drives, switches, cameras, routers and web interfaces |
| Turn off services you do not use | Web server, FTP, Telnet, SNMPv1/2, discovery protocols, unused protocol ports |
| Disable unused physical ports | Switch ports and USB |
| Enable the controller’s protection | PLC project password, know-how protection, access levels, secure communication (Siemens access protection levels, Rockwell FactoryTalk Security and CIP Security, Omron and Mitsubishi security keys) |
| Use the key switch or mode switch | Keep the controller in RUN when not being programmed |
| Keep firmware current | Read the manufacturer’s security advisories; test updates before installing |
| Secure the PCs | Patched operating system, antivirus or application allow-listing, no email or web browsing on engineering and SCADA PCs, disk encryption on laptops |
| Set time | NTP everywhere so that logs line up |
| Remove test and temporary equipment | Taps, jumpers, sniffers and temporary firewall rules |
Passwords and accounts
A password protects only as well as it resists guessing. The number of possibilities grows by a factor of 95 (the number of printable characters) with each extra character, so length matters more than complexity rules.
Worked example: how long to guess a password?
- An attacker with a stolen password hash and a fast graphics card can try about 109 guesses per second.
- 8 characters from 95 symbols: 958 = 6.6 × 1015 possibilities, 77 days to try them all.
- 12 characters: 9512 = 5.4 × 1023, about 1.7 × 107 years.
- 16 characters: 9516 = 4.4 × 1031, beyond any practical attack.
- A common word, a name or a keyboard pattern is not random: a list of the million most-used passwords is tried in about a millisecond. Default vendor passwords are in every such list.
- So: use a long passphrase of 14 characters or more, use a different one for each system, never reuse them, and store them in a password manager or a locked procedure.
- Individual accounts and roles (operator, maintenance, engineer, administrator) with only the rights each needs.
- No shared accounts for people; service accounts only for software, with long random passwords.
- Remove accounts when people leave or contracts end.
- Break-glass access: a sealed, logged emergency account.
- Multi-factor authentication on every remote and administrative login where the system allows.
- Record the controller passwords in a secure place: a lost PLC password can mean the program must be rewritten.
Security of each protocol
| Protocol | Built-in security | What to do |
|---|---|---|
| Modbus RTU / TCP | None | Segmentation, allow lists; Modbus/TCP Security (TLS, port 802) if both ends support it |
| EtherNet/IP and CIP | CIP Security (TLS, certificates, user authentication) on newer devices | Enable CIP Security where supported; otherwise segmentation |
| PROFINET | Security classes (authenticated devices, secure start of communication) in newer specifications | Use segmentation; use security class where devices support it |
| S7 communication | Access protection levels and a connection password; TLS for S7-1500 | Protect the CPU; disable PUT/GET when not needed; use TLS |
| Omron FINS, Mitsubishi MC protocol | Mostly none | Segmentation; restrict which addresses may connect |
| OPC UA | Built in: certificates, signing, encryption, user authentication | Sign and Encrypt; no Anonymous; manage certificates |
| MQTT | TLS and authentication if configured | Port 8883, client certificates or strong credentials, topic ACLs |
| HTTP, Telnet, FTP, SNMPv1/2 | None | Use HTTPS, SSH, SFTP and SNMPv3, or disable |
| PROFIBUS, DeviceNet, CAN | None | Physical security; keep them inside the machine |
Wireless, USB and removable media
- Wi-Fi on the machine network: WPA3 or WPA2-Enterprise, a separate VLAN, no guest access, a rogue access point scan.
- Cellular and radio links: private APNs or VPNs; change default passwords on routers; avoid port forwards.
- Bluetooth and NFC service ports on drives and sensors: disable if not used.
- USB sticks: a major route for malware. Scan them at a station before connecting; use a dedicated, labeled stick for the machine.
- Laptops: a contractor’s laptop is the same risk as a stick. Use a clean laptop policy or a scanning station before connecting to the machine network.
- Engineering software licenses and dongles belong in a secured place.
Monitoring, logging and backup
| Measure | What it gives you |
|---|---|
| Logs | Firewall, switch, PC and PLC logs, sent to one place (a syslog server) with synchronized time |
| Passive network monitoring | A tool on a mirror port learns the normal conversations and alerts on new devices, new connections or new commands, without sending anything onto the network |
| Asset inventory | A list of every device, firmware version and owner; you cannot protect what you do not know you have |
| Configuration backups | PLC programs, HMI projects, drive parameters, switch and firewall configurations, stored off the machine and tested |
| Change management | Every change recorded: who, what, when, why; compare online and offline versions to find unauthorized changes |
| Recovery plan | How to restore from backups and bring a line back up; practiced, not only written |
IEC 62443 in practice
IEC 62443 is the family of standards for industrial automation and control system security. It covers the owner’s program, the integrator’s work, the system design and the product’s development, and defines how secure a zone must be.
| Part | Subject | Who uses it |
|---|---|---|
| 62443-2-1 | Security management system for the asset owner | Plant owners |
| 62443-2-4 | Security program requirements for service providers (integrators, maintenance) | System integrators and machine builders |
| 62443-3-2 | Security risk assessment and system design: zones and conduits | Owners and integrators |
| 62443-3-3 | System security requirements and security levels | Integrators, owners |
| 62443-4-1 | Secure product development lifecycle | Product makers |
| 62443-4-2 | Technical security requirements for components | Product makers, buyers |
| Security level | Protects against | Typical example |
|---|---|---|
| SL 1 | Casual or accidental violation | Mistakes, curious staff |
| SL 2 | Intentional violation with simple means, low resources, generic skills | A casual attacker |
| SL 3 | Intentional violation with sophisticated means, moderate resources, system-specific skills | Targeted criminals |
| SL 4 | Intentional violation with sophisticated means, extended resources, system-specific skills | State-level actors |
The practical use: ask suppliers whether their products are certified or developed to 62443-4-1 and -4-2, and describe the target level for each zone in the project specification.
When something goes wrong
- 1. Keep the process safe. Switch to manual or a safe state first; production second.
- 2. Contain. Disconnect the affected zone at the firewall or switch, not by turning off devices (which destroys evidence and may trip the process).
- 3. Preserve evidence. Keep the logs, take images of infected PCs, note the times.
- 4. Call the right people: the plant manager, the IT security team, the supplier, and where required the authorities.
- 5. Restore from known-good backups, check the controller programs against the saved copies, and change the passwords.
- 6. Find out how it happened and fix the cause; record the lessons.
- Practice with a tabletop exercise: a plan that has never been tried does not work when it is needed.
A machine-builder checklist
| Item | Done when |
|---|---|
| Network design | A diagram with zones, addresses and the rules between them |
| Remote access | One documented path; no hidden cellular router; the customer’s approval |
| Defaults | Every default password changed; the new ones handed over securely |
| Services | Unused protocols, web pages and ports disabled |
| Firewall rules | Allow list reviewed; default deny |
| Program protection | Controller passwords set; mode switch in RUN |
| Backups | All programs, parameters and switch configs saved, tested, handed over |
| Documentation | Address and port list, account list, firmware versions, patch policy |
| Training | The customer knows the rules and the incident plan |
Related
- Industrial Communication: the overview of this guide.
- IP Addressing, Subnets and VLANs: addresses, VLANs and ports that the firewall rules name.
- OPC UA, MQTT and Industrial IoT: OPC UA and MQTT security.
- Industrial Ethernet: EtherNet/IP, PROFINET and EtherCAT: managed-switch features used for segmentation.
- System Integration and PLC Troubleshooting, Safety and Documentation.
FAQ
Is a firewall enough?
No. A firewall is one layer. It does nothing about an infected laptop on the inside, a default password or an unpatched device. Use layers: segmentation, hardened devices, strong accounts, monitoring and backups.
Can I just put the machine on a separate network and call it secure?
It is a good start, and it removes most attacks from the office. But the machine still has a service laptop, USB sticks, a remote-access path and vendor connections. Secure those too.
Do I need to patch a PLC?
Read the manufacturer’s security advisories. Patch when a flaw is exploitable in your setting, after testing, during planned downtime. Where you cannot patch, reduce the exposure with segmentation and allow lists (virtual patching).
Is NAT a security measure?
No. NAT hides addresses but does not block connections from the inside or from an attacker who is already in. It is a convenience for address reuse; the firewall rules provide the security.
Who is responsible, the builder or the owner?
Both: the builder delivers a secure product and documentation (62443-4 and 2-4); the owner operates a security program (62443-2-1). Agree this in the contract.
Where do I start?
Draw the network, list the devices, close the internet exposure, change the default passwords and take backups. These four steps remove most of the risk.
References
- IEC 62443 series, Security for industrial automation and control systems, especially 62443-2-1, 2-4, 3-2, 3-3, 4-1 and 4-2.
- NIST SP 800-82 Rev. 3, Guide to Operational Technology (OT) Security.
- CISA, Recommended Practices for Improving Industrial Control System Cybersecurity and Defense-in-Depth Strategies (cisa.gov/ics).
- Rockwell Automation and Cisco, Converged Plantwide Ethernet (CPwE) Design and Implementation Guide; Siemens, Operational Guidelines for Industrial Security.
- ODVA, CIP Security; OPC Foundation, OPC UA Security; Modbus Organization, MODBUS/TCP Security Protocol Specification.
- Purdue Enterprise Reference Architecture (PERA), as used in ISA-95.
Last reviewed: October 2026. Speeds, lengths, node counts and menu names are typical: confirm against the specification and the manufacturer’s documentation for the devices you use. This page gives general guidance and is not a substitute for a security assessment of your site by qualified people.