Switches, Connectors and Protection

Switch types and ratings, connector families, fuses, reverse-polarity and surge protection, and wiring good practice.

Switches

A switch opens or closes a connection by hand. Two numbers name its action: the poles (how many separate circuits it switches) and the throws (how many positions each pole can connect to). SPST is single pole, single throw (on/off); SPDT is a changeover; DPDT switches two circuits at once.

SPSTon / offSPDTchooses one of twoPush button N.O.closed only while pressedPush button N.C.open only while pressedCOMNONC
Four common switch symbols. Normally open (N.O.) is open at rest; normally closed (N.C.) is closed at rest.
TypeUseNotes
Toggle, rocker, slidePower on/off, mode selectionStay in position; rocker switches often come with a lamp
Tactile (tact) buttonUser input to a microcontrollerMomentary; 12 V 50 mA is a typical rating; not for power
Push-button (panel)Start, stop, emergency stopIndustrial types have N.O. and N.C. contacts and a latching or momentary action
Rotary / DIP switchSettings, addressesRotary encoders turn into pulses; see Sensors
Limit / micro switchDetecting position or a doorLever or roller actuator; use the N.C. contact for fail-safe detection
Reed switchMagnet detectionSealed contacts in glass; no wear, limited current
Key switch, selectorAccess control, modePanel mount; check the rating

Switch ratings and contact bounce

  • Current and voltage rating. Every switch has a maximum current at a given voltage, often two figures: “3 A 250 V AC / 6 A 125 V AC”. The DC rating is usually much lower than the AC rating because a DC arc does not go out by itself; if only the AC rating is given, derate heavily for DC.
  • Inductive and lamp loads (motors, solenoids, relays, capacitive supplies, incandescent lamps) make arcs and surges when switched. Derate to half or less of the rating, add a flyback diode or snubber, and consider a relay or MOSFET.
  • Low-level (“dry circuit”) contacts. A big power switch may not make a reliable contact at a few milliamps. For signals, use a switch rated for small currents (gold-plated contacts).
  • Contact bounce. When a mechanical contact closes, it bounces for 1–10 ms, producing a burst of on/off transitions. A microcontroller reads each one as a separate press.

Debouncing

  • In software: ignore further changes for 20–50 ms after the first edge, or require the same reading several times in a row. This is free and usually enough.
  • In hardware: an RC filter across the switch (for example 10 kΩ and 100 nF, τ = 1.0 ms) with a Schmitt-trigger input (74HC14) smooths the bounce.
  • Interrupt inputs are especially sensitive to bounce and need one of the above.

Connectors

ConnectorPitch / sizeTypical ratingNotes
Pin header / Dupont2.54 mm1 A per pinBreadboards and hobby modules; no keying or lock, so mind the orientation
JST-PH2.0 mm2 ASmall LiPo batteries and sensors; polarized
JST-XH2.5 mm3 AKeyed, secure; balance leads and boards
JST-SH / Qwiic / STEMMA QT1.0 mm1 AI²C sensor cables
Molex KK2.54 mm3 AKeyed, friction lock; widely used
Screw terminal3.5, 5.0, 5.08 mm8–16 ANo crimp tool; good for field wiring
XT30 / XT60 / XT90—15 A / 30 A / 40 A+Hobby batteries and motors; polarized; avoid arcing on connect
Barrel jack5.5 × 2.1 mm2–5 ACenter-positive is the common convention, but check: there is no standard
USB-A / micro / USB-C—0.5–3 A (5 V); to 5 A with PDData and power; USB-C negotiates the voltage
Anderson Powerpole—15–45 AGenderless; any pairing, so label polarity
  • Polarity and keying. Choose connectors that cannot be plugged in backwards, or mark them clearly. A reversed power plug is a common way to destroy a board.
  • Crimped, not soldered. A proper crimp is gas-tight and stronger than solder; use the crimp tool made for the terminal. Solder wicks up the wire and makes it brittle. See Soldering for wire and strain relief.
  • Current rating is per contact and at a temperature rise; derate when many contacts carry current in a bundle or when the connector is warm.
  • Locking. Use a latching connector where vibration or tugging is likely (motors, vehicles, robots).
  • Wire gauge. Match the wire to the connector and to the current; see the AWG table in Soldering and System Integration for voltage drop.

Fuses and circuit breakers

A fuse is a deliberate weak link: a thin conductor that melts and opens the circuit when the current is too high for too long. It protects the wiring (so it does not overheat and start a fire) and limits the damage a fault can do.

TypeBehaviorNotes
Fast-blow (F)Opens quickly on overloadProtects delicate electronics
Slow-blow / time-delay (T)Tolerates a short surge (motor start, supply inrush)For loads with inrush current
Blade (automotive)32 V DC, 1–40 AStandard in vehicles; color-coded by rating
Resettable polyfuse (PTC)Resistance rises sharply when hot, resets when coolConvenient for USB and small boards; slow and not for mains
Thermal fuseOpens above a temperature, onceIn heaters and transformers
Circuit breakerResettable switch that tripsPanels and larger supplies
  • Choose the current: above the normal running current (typically 125–150 % of it, or higher for loads with inrush), and always below the safe current of the wire and connectors. The fuse protects the weakest part of the path.
  • Choose the voltage: the fuse’s voltage rating must be at least the circuit voltage (DC ratings are lower than AC ratings).
  • Place it near the source (the battery or supply), so the whole run of wire is protected.
  • Interrupt rating: a fuse must be able to break the maximum fault current the supply can deliver (a car or lithium battery can supply hundreds of amps). Use a fuse with a suitable breaking capacity.
  • Replace a fuse with the same rating, never with a bigger one or a wire. Find out why it blew first.

Worked example: a 12 V, 3 A LED strip on AWG 18

  • Running current is 3 A. A fuse of 125–150 % gives 3.75–4.5 A, so a standard 5 A fuse suits.
  • AWG 18 chassis wire is commonly rated at about 7 A, so it is protected by a 5 A fuse. (Use the maker’s table for your insulation and bundle.)
  • Place the fuse within 150 mm of the supply’s positive terminal.

Reverse-polarity protection

Connecting a battery or supply backwards destroys polarized parts in an instant. Where it can happen, add protection.

Reverse polarity: series diodeOvercurrent and surge: fuse and TVSLoad1N5819batteryBackwards battery: the diode blocks it.Cost: about 0.3 to 0.7 V and power in the diode(0.5 V × 1 A = 0.5 W). A P-channel MOSFET loses far less.2 A fuseTVSLoadThe TVS clamps voltage spikes (for examplea motor or a long cable). If a part fails short,the fuse opens before the wiring overheats.
A series diode blocks a reversed supply at the cost of a voltage drop. A fuse and TVS protect against overcurrent and surges.
MethodLossComment
Series diode0.3–0.7 VSimplest. At 1 A the loss is 0.5 W for a 0.5 V drop: poor for a low-voltage battery
Bridge rectifier1.4 VAccepts either polarity (and AC) but wastes the most
P-channel MOSFET in the positive line (source toward the load; gate to ground through a resistor)I² × RDS(on): 0.03 W at 1 A and 30 mΩThe body diode conducts initially, then the gate turns the MOSFET on: almost no loss. Check the gate-source voltage limit (typically ±20 V)
Diode across the supply plus a fuseNone in normal useA reversed supply blows the fuse; slower and needs replacing
Polarized connectorNonePrevents the mistake; always use as well

Surge, static and spike protection

  • TVS diode across the supply or a data line clamps spikes (long cables, motors, hot-plugging, mains-borne surges). Pick a standoff voltage above the normal voltage and a clamp voltage below the maximum the circuit can survive.
  • ESD protection on exposed connectors (USB, buttons, headers) with low-capacitance TVS arrays. Static discharges of several kilovolts are common on a dry day.
  • Inrush limiting. A large capacitor charges with a big surge when power is first applied. An NTC thermistor in series, or a soft-start circuit, limits it.
  • Series resistors (100 Ω to 1 kΩ) on I/O lines limit the current that a spike or a mistaken connection can push into a pin.
  • Clamp diodes. Two diodes (one to the supply, one to ground) catch any input that goes beyond the rails.
  • Flyback diode across every relay and motor coil (see Inductors, Transformers and Relays).

Good practice

  • Label polarity and voltage at every power connector, and use red for positive and black for ground.
  • Power switch and fuse first. The path from the source goes: connector, fuse, switch, protection, then the circuit.
  • Star grounding. Bring noisy grounds (motors) back to the supply separately from quiet analog grounds, rather than daisy-chaining.
  • Strain relief at every connector and joint, so the wire cannot be pulled out or flexed where it is soldered.
  • Test before connecting a load. Measure the supply voltage and polarity with a meter before plugging in a board (see Test Tools and Fault Finding).
  • Enclose mains wiring and keep it separate from low-voltage wiring. Follow the electrical code for any mains work.

Related

FAQ

Why does my button press register several times?

The contacts bounce when they close, making a burst of transitions for a few milliseconds. Debounce in software by ignoring changes for 20–50 ms, or add an RC filter and a Schmitt-trigger input.

Can I use an AC-rated switch on a DC circuit?

Only with heavy derating. DC arcs do not extinguish at a zero crossing, so a switch rated 10 A at 250 V AC may handle only a fraction of that at 24 V DC. Use the DC rating, or a switch made for DC.

Which fuse should I use?

Choose one above the normal current (125–150 %) but safely below the rating of the wire and connectors; check the voltage rating and the interrupt rating; and use slow-blow if the load has inrush.

Is a series diode good enough for reverse protection?

It works, but it drops 0.3–0.7 V and dissipates heat. For a battery-powered circuit where every volt counts, use a P-channel MOSFET instead; for a simple mains adapter input, a diode is fine.

What is the difference between a TVS and a varistor?

Both clamp surges. A TVS clamps faster and more precisely and recovers; a varistor (MOV) handles bigger energy and is used across mains inputs, but degrades with repeated surges.

References

  • Horowitz, P. and Hill, W., The Art of Electronics, 3rd ed., Cambridge University Press.
  • Manufacturer datasheets and selection guides: JST, Molex, Amass (XT connectors), Littelfuse and Bussmann (fuses), Omron and C&K (switches).
  • UL 248 and IEC 60127, fuse standards; NFPA 70 (NEC) for wiring and overcurrent protection.
  • Ganssle, J., A Guide to Debouncing, The Ganssle Group (contact bounce measurements and fixes).

Last reviewed: October 2026. Values are typical: check the datasheets of the parts you use. Follow the electrical code for any mains work.