Fourier’s Law of Heat Conduction Formula
Fourier’s law gives the heat flow through a solid wall: Q = k A (T hot – T cold) / L. Enter the conductivity, area, thickness and the two surface temperatures.
How it works
Fourier’s law says the heat flowing by conduction is proportional to the temperature difference across the material and the area, and inversely proportional to the thickness. It is the starting point for insulation, furnace walls, heat sinks and every thermal resistance calculation.
Q = k × A × (Thot − Tcold) ÷ L
q = Q ÷ A
R = L ÷ (k A)
| Symbol | Meaning | SI unit |
|---|---|---|
| Q | Heat flow rate | W |
| k | Thermal conductivity of the material | W/(m·K) |
| A | Area the heat passes through (perpendicular to the flow) | m² |
| T hot, T cold | Surface temperatures on the two faces | K or °C |
| L | Thickness of the wall in the flow direction | m |
| q | Heat flux, heat flow per unit area | W/m² |
| R | Thermal resistance of the wall | K/W |
For a wall made of several layers in series, add the resistances: Rtotal = L1/(k1A) + L2/(k2A) + …, and the heat flow is ΔT ÷ Rtotal. Typical conductivities: copper 400, aluminum 205, carbon steel 50, stainless steel 16, glass 1.0, brick 0.7, wood 0.15, mineral wool 0.04, still air 0.026 W/(m·K).
Related: Heat Transfer guide, Heat Sink and Thermal Resistance Calculator. All formulas are listed in the Formulas library.
Worked example
A brick wall with k = 0.72 W/(m·K), 10 m² of area and 200 mm thickness, with 20 °C inside and −5 °C outside: Q = 0.72 × 10 × 25 ÷ 0.2 = 900 W. The heat flux is 90 W/m² and the wall resistance is 0.0278 K/W.
Add 100 mm of mineral wool (k = 0.04): the resistance rises by 0.1 ÷ (0.04 × 10) = 0.25 K/W, nearly ten times the brick alone, and the heat loss falls to about 90 W.
Things to know
The formula is for steady, one-dimensional conduction through a flat wall. Pipes and spheres use logarithmic and reciprocal forms (Q = 2π k L ΔT ÷ ln(r₂/r₁) for a pipe).
Use the temperatures of the two surfaces, not the air on either side. If you know the air temperatures, add the surface (film) resistances 1/(hA) on each side.
Conductivity changes with temperature and moisture. Wet insulation can lose most of its value.
Common questions
What is Fourier’s law?
Fourier’s law states that the heat flux by conduction is proportional to the negative temperature gradient: q = −k dT/dx. For a flat wall in steady state it becomes Q = k A ΔT ÷ L.
What is the formula for conductive heat transfer?
Q = k A (T1 − T2) ÷ L, where k is the thermal conductivity in W/(m·K), A the area in m², the temperatures are in kelvin or degrees Celsius, and L the thickness in meters.
What are the units of thermal conductivity?
W/(m·K) in SI, or BTU/(h·ft·°F) in US units. One BTU/(h·ft·°F) equals 1.731 W/(m·K).
How do you calculate thermal resistance of a wall?
R = L ÷ (k A) in K/W. Layers in series add. The heat flow is then ΔT ÷ R_total.
Sources
- Incropera, F. P. et al., Fundamentals of Heat and Mass Transfer, Wiley: conduction rate equation.
- Typical conductivities from the ASHRAE Handbook, Fundamentals, and Incropera Appendix A.
Last reviewed: November 10, 2026