Euler Buckling Calculator (Critical Load of a Column)
Calculate the critical buckling load of a column with Euler’s formula and the Johnson parabola, from the section, material, length and end conditions, with the slenderness ratio and a factor of safety.
How it works
A slender column loaded in compression fails by buckling, sideways bending, at a load well below the one that would crush the material. The Euler critical load is the load at which a perfectly straight, elastic column becomes unstable.
Pcr = π² E I ÷ (K L)²
E is the modulus of elasticity, I the second moment of area about the weaker axis, L the length and K the effective length factor set by the end conditions. K L is the effective length: the length of an equivalent pin-ended column.
The slenderness ratio is K L ÷ r, with r = √(I ÷ A) the radius of gyration. The critical stress σcr = π² E ÷ (K L ÷ r)² falls as the column gets more slender. The effective length factors are K = 1 for pinned ends, 0.5 for two fixed ends, 0.7 for fixed and pinned, and 2 for fixed and free (a flagpole). Fixed-fixed carries four times the load of pinned-pinned; fixed-free a quarter.
Euler’s formula only holds while the buckling stress stays below the proportional limit. Below the transition slenderness Cc = √(2 π² E ÷ Sy) the column is stocky and yields before it buckles. For these intermediate columns the page uses the Johnson parabola, Pcr = A [Sy − Sy² (K L ÷ r)² ÷ (4 π² E)], which meets Euler’s curve at Cc and equals the yield load for a very short column. The chart shows both curves and your column.
A real column also has an initial crookedness, off-center load, residual stress and imperfect supports, so apply a factor of safety (commonly 2 to 3, more for long or critical columns). Section properties for the buckling axis come from the Moment of Inertia and Radius of Gyration Calculator.
Worked example
A 20 mm steel round bar, 1 m long, pinned at both ends: I = π d⁴ ÷ 64 = 7,854 mm⁴, A = 314.2 mm² and r = d ÷ 4 = 5 mm, so the slenderness K L ÷ r = 1 ÷ 0.005 = 200. The transition slenderness for A36 steel is Cc = 125.7, so this is a slender column and Euler governs: Pcr = π² × 200 × 10⁹ × 0.000000007854 ÷ 1² = 15.50 kN (49.3 MPa, far below yield). With a factor of safety of 3 the allowable load is 5.17 kN.
The same bar 0.3 m long: K L ÷ r = 60, below Cc. Euler would give 172.3 kN, more than the yield load A Sy = 78.5 kN, which is impossible. The Johnson parabola gives 69.6 kN. This is why Euler’s formula must not be used for short columns.
End conditions: the 1 m bar fixed at both ends (K = 0.5) carries 62.0 kN, four times as much, and fixed at one end and free at the other (K = 2) only 3.88 kN.
Things to know
Use the second moment of area about the weaker axis. A column buckles about the axis with the smaller radius of gyration unless it is braced differently in the two directions. For an I-beam or a rectangle that is the minor axis.
The effective length factors are for ideal supports. A real “fixed” end is never fully rigid, so design practice (for example AISC) recommends K = 0.65 instead of 0.5 for two fixed ends, 0.8 instead of 0.7 for fixed and pinned, and 2.1 instead of 2.0 for fixed and free. Choose “Other” and enter your own K.
Euler’s load is a theoretical maximum for a perfect column. Imperfections reduce it, especially for slenderness between about 60 and 120. Design codes (AISC, Eurocode 3, AISI) use column curves with imperfection factors: use them for structural design.
Local buckling of thin walls (thin tubes, flanges and webs of light sections) can occur before column buckling; check the width-to-thickness ratios for thin sections.
A slenderness ratio over about 200 is generally avoided. Reduce K L (brace the column mid-length), or enlarge the section.
This calculator is for checking an axially loaded column. It does not include bending from eccentric loads: add the bending stress and use an interaction formula (a beam-column).
Common questions
What is the Euler buckling formula?
P = π² E I ÷ (K L)². P is the critical load, E the modulus of elasticity, I the second moment of area about the weaker axis, L the length and K the effective length factor for the end supports.
What is the effective length factor K?
It converts the real column to an equivalent pin-ended one. K = 1 for both ends pinned, 0.5 for both fixed, 0.7 for one fixed and one pinned and 2 for one fixed and one free.
What is the slenderness ratio?
K L ÷ r, the effective length divided by the radius of gyration. Above about 100 to 120 for steel the column is slender and Euler’s formula applies; below the transition value Cc the Johnson or another empirical formula is used.
What is the critical load for a column?
The compressive load at which a straight column becomes unstable and bows sideways. In the Euler case it is independent of the strength of the material (it depends on E), which is why high-strength steel does not make a slender column stronger.
When does Euler’s formula not apply?
For short or stocky columns where the buckling stress would exceed about half the yield strength (slenderness below Cc). There the column fails by yielding and the Johnson formula is used.
How do I find the critical load of a column in pounds?
Choose the inch units in the boxes (or switch to US units): enter the section in inches, the length in feet or inches, and E in Msi (29 Msi for steel). The load comes out in lbf or kip.
Sources
- Euler, L., 1744, on the elastic curve; Johnson, J. B., 1886, short column formula.
- Gere, J. M., Goodno, B. J., Mechanics of Materials: columns, effective length factors and the Johnson formula.
- Shigley, J. E., Mischke, C. R., Mechanical Engineering Design: column design, Euler and Johnson curves.
- AISC 360 Specification for Structural Steel Buildings, chapter E, and EN 1993-1-1 for design column curves.
Last reviewed: November 2, 2026
