Orifice Plate Flow Calculator (ISO 5167)

Calculate the flow through an orifice plate from the differential pressure (or the pressure drop or bore size) for liquids and gases, with the discharge coefficient from ISO 5167-2.

How it works

An orifice plate is a thin plate with a round, sharp-edged hole placed across a pipe. The flow speeds up through the hole and the pressure falls; the pressure difference across the plate (measured at the taps) is a measure of the flow rate. It is the most common way to measure the flow of liquids, gases and steam in a pipe.

qm = C ÷ √(1 − β⁴) × ε × (π ÷ 4) d² × √(2 Δp ρ)

qm is the mass flow, C the discharge coefficient, β = d ÷ D the diameter ratio, ε the expansibility factor (1 for liquids), d the bore, Δp the differential pressure and ρ the upstream density. The volumetric flow is qm ÷ ρ.

The discharge coefficient C (about 0.6 for a sharp-edged orifice) depends on β, the pipe size and the Reynolds number. The page uses the Reader-Harris/Gallagher equation of ISO 5167-2 for corner taps and iterates, because C depends on the Reynolds number, which depends on the flow. For gases the expansibility factor ε = 1 − (0.351 + 0.256 β⁴ + 0.93 β⁸) [1 − (p₂ ÷ p₁)1/κ] allows for the gas expanding as the pressure falls.

After the plate the flow recovers part of the pressure. The permanent pressure loss is Δp × [√(1 − β⁴(1 − C²)) − C β²] ÷ [√(1 − β⁴(1 − C²)) + C β²]: about 82 percent of Δp at β = 0.4, 73 percent at 0.5, 63 percent at 0.6 and 50 percent at 0.7, so a smaller bore costs pumping energy. Use the pressure-drop mode to size a plate for a flow, or the bore mode to find the hole for a given flow and the pressure drop you can accept. The pipe and fluid properties come from the pipe flow calculator and the water and air tables.

Worked example

Water at 20 °C in a 100 mm pipe through a 50 mm bore with a 20 kPa pressure drop: β = 0.5. The Reynolds number of the flow is about 98,844 and the discharge coefficient comes to C = 0.6069. The mass flow is 7.777 kg/s, which is 7.79 L/s (28.0 m³/h, 123 US gpm). The velocity is 0.99 m/s in the pipe and 3.97 m/s through the hole, and the permanent pressure loss is 14.6 kPa (73 percent of the differential pressure).

Air at 20 °C and 500 kPa abs, 10 kPa across the same plate: the density is 5.94 kg/m³ and the expansibility factor 0.9947, so the mass flow is 0.421 kg/s (255 m³/h at the upstream conditions). Treating the air as incompressible would overstate the flow by about 0.5 percent.

Things to know

The standard (ISO 5167-2) covers pipes of 50 to 1,000 mm, β from 0.1 to 0.75 and a minimum Reynolds number of about 5,000 (16,000 β² for large β). The page warns when you are outside it. Orifice plates measure poorly at low flow.

The calculation assumes a sharp-edged plate in good condition, with straight pipe upstream (10 to 40 diameters, depending on the fittings) and downstream, and a pipe full of single-phase fluid. Wear, dirt and rounding of the edge change C and reduce the accuracy; a flow computer or a recalibration is needed for custody transfer.

Use the actual inside diameter of the pipe (the Schedule 40 or 80 chart gives it) and the bore measured at the working temperature. Thermal expansion of the plate and the pipe is neglected.

The differential pressure is the pressure measured at the corner taps. Flange taps and D and D/2 taps give slightly different coefficients; the Reader-Harris/Gallagher equation changes with the tap positions.

For gases give the absolute pressure upstream and the density at that pressure and temperature. The page computes the density of air from the ideal gas law; for steam and other gases enter the density and isentropic exponent.

Because flow varies as the square root of Δp, a flow turndown of 3:1 means a differential pressure range of 9:1; this limits the useful range of one plate.

Common questions

How do you calculate flow through an orifice?

q = C ÷ √(1 − β⁴) × ε × (π ÷ 4) d² × √(2 Δp ρ) for the mass flow, with β = d ÷ D, the discharge coefficient C (about 0.6), the expansibility factor ε (1 for liquids) and the differential pressure Δp.

What is the discharge coefficient of an orifice plate?

About 0.60 to 0.61 for a standard sharp-edged plate over a wide range of β and Reynolds numbers. ISO 5167-2 gives the exact value from the Reader-Harris/Gallagher equation, which this calculator uses.

What beta ratio should I use?

Between 0.2 and 0.7 is usual. A smaller β gives a bigger differential pressure and a better signal, but a larger permanent loss and more sensitivity to edge wear; a larger β loses less pressure but is more sensitive to the upstream pipe and the taps.

What is the permanent pressure loss of an orifice plate?

Part of the differential pressure is recovered downstream. The permanent loss is about 82 percent of Δp at β = 0.4, 73 percent at 0.5, 63 percent at 0.6 and 50 percent at 0.7: it grows as β falls.

Can I use this for steam or natural gas?

Yes, with the “Other gas” option: enter the upstream absolute pressure, the density at the upstream condition, the viscosity and the isentropic exponent (about 1.3). The method is the same.

Where do the pressure taps go?

For corner taps, one tap on each face of the plate; for flange taps 25.4 mm (1 in) each side; for D and D/2 taps one pipe diameter upstream and half a diameter downstream. This calculator uses corner taps.

Sources

  • ISO 5167-1:2022 and ISO 5167-2:2022, Measurement of fluid flow by means of pressure differential devices: orifice plates (discharge coefficient, expansibility factor, pressure loss).
  • Reader-Harris, M. J. and Gallagher, J. E., The Reader-Harris/Gallagher equation for the discharge coefficient of orifice plates.
  • Miller, R. W., Flow Measurement Engineering Handbook, McGraw-Hill.

Last reviewed: November 2, 2026

Published by Nick Peterson, mechanical engineer.