Bolt Torque Formula
Bolt torque T = K x F x d. Enter the preload, the bolt diameter and the friction condition to get the tightening torque, or enter the torque to find the preload it produces.
How it works
Tightening a bolt stretches it like a spring, and the stretch is the clamp load (preload) that holds the joint together. Most of the torque you apply is lost to friction, so the usual short-cut relates torque to preload through a nut factor K.
T = K × F × d
F = T ÷ (K × d)
preload target: F ≈ 0.75 × proof load (reused joints) or 0.9 × proof load (permanent)
| Symbol | Meaning | SI unit |
|---|---|---|
| T | Tightening torque | N·m |
| K | Nut factor (torque coefficient) | – |
| F | Preload (clamp force) in the bolt | N |
| d | Nominal bolt diameter | m |
The nut factor combines the thread and under-head friction in one number. Typical values are 0.20 for plain steel dry or as received, 0.17 for zinc plated, 0.15 for lightly oiled, and 0.10 to 0.12 for waxed or molybdenum disulfide coated threads. Friction scatters widely, so the real preload from a given torque varies by about ±25 percent; use torque-angle or direct tension indicators for critical joints.
Roughly 90 percent of the torque is lost to friction: about 50 percent under the head or nut face, 40 percent in the threads, and only about 10 percent becomes useful stretch. That is why lubricating a bolt without lowering the torque can over-tighten and yield it. The torque tables and the Bolt Torque Tool use these values for ISO metric bolts.
Related: Structures and Strength of Materials guide (bolted and welded joints), Bolt Torque and Thread Engagement Tool, Bolt Tightening Torque Table (metric), Bolt Grades and Property Classes. All formulas are listed in the Formulas library.
Worked example
An M10 class 8.8 bolt, dry: the stress area is 58 mm² and the proof strength 580 MPa, so the proof load is 33.6 kN. A preload of 75 percent of that is 25.2 kN, say 25 kN. The torque is T = 0.20 × 25,000 N × 0.010 m = 50 N·m (36.9 lbf·ft).
Lightly oil the same thread (K = 0.15) and the same 50 N·m produces F = 50 ÷ (0.15 × 0.010) = 33.3 kN, which is 99 percent of the proof load: close to yield. To get the same 25 kN with oil you would need only 37.5 N·m.
Things to know
The formula gives a nominal torque, not a precise preload. Torque wrenches themselves are accurate to about ±4 percent, and friction scatters far more.
Check the thread condition before using a table. A tightening torque for dry threads must be reduced when the threads are oiled, greased or coated.
Do not exceed the proof load. Tightening beyond about 90 percent of proof risks permanent stretch. For critical joints specify a tightening method (torque-angle, hydraulic tensioner or a direct tension indicator) rather than only a torque.
Common questions
What is the formula for bolt torque?
T = K × F × d: the nut factor times the preload times the nominal bolt diameter.
What is the nut factor K?
A dimensionless friction coefficient for the whole fastener: about 0.20 for dry plain steel, 0.15 for oiled threads and 0.10 to 0.12 for waxed or molybdenum disulfide coated threads.
How do you calculate bolt preload from torque?
F = T ÷ (K × d). For example 50 N·m on an M10 bolt with K = 0.20 gives 25 kN.
What preload should a bolt have?
About 75 percent of the proof load for a joint that will be taken apart and 90 percent for a permanent one.
How accurate is torque as a measure of bolt tension?
Not very: the preload from a given torque typically varies ±25 percent because of friction. Use a calibrated method for critical joints.
Sources
- Bickford, J. H., An Introduction to the Design and Behavior of Bolted Joints, CRC Press.
- Shigley, J. E. et al., Mechanical Engineering Design, McGraw-Hill: bolt tightening and preload.
- ISO 898-1: Mechanical properties of fasteners (proof loads).
Last reviewed: November 10, 2026