Euler Buckling Formula
Euler critical buckling load Pcr = pi^2 E I / (K L)^2. Enter the modulus, section properties, length and end conditions for the load, the stress and the slenderness ratio.
How it works
A long slender column under compression can fail by buckling (sideways bowing) at a load far below the crushing load. Euler’s formula gives that critical load from the stiffness of the material and the section, the length and how the ends are held.
Pcr = π² × E × I ÷ (K × L)²
σcr = Pcr ÷ A
slenderness = K L ÷ r, r = √(I ÷ A)
| Symbol | Meaning | SI unit |
|---|---|---|
| P_cr | Critical (buckling) load | N |
| E | Young’s modulus | Pa |
| I | Smallest area moment of inertia of the section | m⁴ |
| L | Unsupported length of the column | m |
| K | Effective length factor from the end conditions | – |
| A | Cross-section area | m² |
| r | Radius of gyration | m |
Effective length factors (theoretical, design values in brackets): pinned-pinned 1.0, fixed-fixed 0.5 (0.65), fixed-pinned 0.7 (0.8), fixed-free (flagpole) 2.0 (2.1). Euler’s formula holds for slender columns, with a slenderness ratio above about 100 for structural steel. For stocky columns the critical stress would exceed the yield strength, and the Johnson parabola or a design code applies. Use a safety factor of at least 2 to 3 on the buckling load.
Related: Structures and Strength of Materials guide (columns), Euler Buckling Calculator (with the Johnson parabola). All formulas are listed in the Formulas library.
Worked example
A 20 mm steel rod, 500 mm long, pinned at both ends: I = π × 20⁴ ÷ 64 = 7,854 mm⁴, A = 314.2 mm², r = 5 mm, so the slenderness is 500 ÷ 5 = 100. Pcr = π² × 200,000 MPa × 7,854 mm⁴ ÷ 500² = 62.0 kN (critical stress 197 MPa).
Clamp both ends and the effective length halves, so the load goes up fourfold to about 248 kN (the stress would then pass the yield strength, so the Johnson formula applies). With one end free it drops to 15.5 kN.
Things to know
Use the smaller moment of inertia: the column buckles about its weak axis.
Buckling load scales with 1 ÷ L²: doubling the length cuts the capacity by a factor of four. It also does not depend on the yield strength, so a higher strength steel does not buckle later.
Imperfections, load eccentricity and out-of-straightness lower the real capacity; codes apply reduction factors. Treat the formula as an upper bound.
Common questions
What is Euler’s buckling formula?
P_cr = π² E I ÷ (K L)², the critical axial load at which a slender column buckles.
What is the effective length factor K?
It adjusts for the end conditions: 1 for pinned ends, 0.5 for fixed ends, 0.7 for fixed-pinned and 2 for fixed-free.
What is the slenderness ratio?
K L ÷ r, with r = √(I ÷ A) the radius of gyration. Euler applies above about 100 for steel. Below that, the column crushes or yields before it buckles elastically.
Does buckling depend on the strength of the material?
Not for slender columns: only the stiffness E matters. Stocky columns do fail at the yield strength.
Sources
- Gere, J. M. and Goodno, B. J., Mechanics of Materials, Cengage: columns.
- AISC Steel Construction Manual: effective length factors and column design.
Last reviewed: November 10, 2026