Heat Transfer Formula
The three heat transfer formulas in one calculator: conduction Q = k A dT / L, convection Q = h A dT and radiation Q = emissivity x sigma x A x (T1^4 – T2^4). Pick the mode and enter your numbers.
How it works
Heat moves in three ways. Conduction carries it through a solid, convection carries it between a surface and a moving fluid, and radiation carries it as electromagnetic waves across any gap. Each has its own formula, and real problems usually combine them.
Conduction: Q = k × A × ΔT ÷ L
Convection: Q = h × A × ΔT
Radiation: Q = ε × σ × A × (T₁⁴ − T₂⁴)
| Symbol | Meaning | SI unit |
|---|---|---|
| Q | Heat transfer rate | W |
| k | Thermal conductivity of the material | W/(m·K) |
| h | Convection heat transfer coefficient | W/(m²·K) |
| A | Surface area | m² |
| ΔT | Temperature difference | K |
| L | Thickness of the wall | m |
| ε | Emissivity of the surface (0 to 1) | – |
| σ | Stefan-Boltzmann constant, 5.670 × 10⁻⁸ | W/(m²·K⁴) |
| T₁, T₂ | Absolute temperatures of the surface and its surroundings | K |
Temperature differences are the same in °C and K, but the radiation formula needs absolute temperatures in kelvin (add 273.15 to °C, or 459.67 to °F to get °R). Typical conductivities: copper 400, aluminum 200, steel 45, brick 0.7, glass 1, wood 0.15, mineral wool 0.04 W/(m·K). Typical convection coefficients: still air 5 to 10, moving air 10 to 100, water 500 to 10,000 W/(m²·K).
In a wall with several layers the thermal resistances add: Rtotal = L₁ ÷ k₁A + L₂ ÷ k₂A + 1 ÷ hA, and Q = ΔT ÷ Rtotal, the same as resistors in series. See the Heat Transfer Calculator for layered walls and cylinders.
Related: Heat Transfer guide, Heat Transfer Calculator (layers, pipes and insulation), Fourier’s law, Convection heat transfer formula, Stefan-Boltzmann law. All formulas are listed in the Formulas library.
Worked example
Conduction through a brick wall: 10 m² of wall 0.2 m thick with k = 0.6 W/(m·K) and a 20 K difference carries Q = 0.6 × 10 × 20 ÷ 0.2 = 600 W (60 W/m²). Insulate with 50 mm of mineral wool (k = 0.04) and the same difference drives only 0.04 × 10 × 20 ÷ 0.05 = 160 W.
Convection: a 1 m² surface at 60 °C in 20 °C still air with h = 10 W/(m²·K) loses 10 × 1 × 40 = 400 W. Radiation: a 1 m² surface with ε = 0.9 at 100 °C facing 20 °C surroundings radiates 0.9 × 5.67 × 10⁻⁸ × (373.15⁴ − 293.15⁴) = 613 W, which is why a hot pipe loses heat even in a vacuum.
Things to know
Use absolute temperatures (kelvin) only in the radiation formula. The calculator converts °C or °F for you, but a hand calculation with °C in the T⁴ terms gives a wrong answer.
The heat transfer coefficient h is not a property of the fluid alone: it depends on the speed, the geometry and the surface. Look up or estimate it for the situation.
Hot surfaces lose heat by convection and radiation together. Add the two rates, or define a combined coefficient, when estimating the total loss from a hot tank or pipe.
Common questions
What is the formula for heat transfer?
It depends on the mode: conduction Q = k A ΔT ÷ L, convection Q = h A ΔT, radiation Q = ε σ A (T₁⁴ − T₂⁴). Heat flows from hot to cold.
What is the formula for heat transfer by conduction?
Fourier’s law, Q = k A ΔT ÷ L: proportional to the conductivity, the area and the temperature difference, and inversely proportional to the thickness.
What is the formula for heat transfer by convection?
Newton’s law of cooling, Q = h A (Tsurface − Tfluid), where h is the convection coefficient.
What is the formula for radiation heat transfer?
Q = ε σ A (T₁⁴ − T₂⁴) with absolute temperatures in kelvin and σ = 5.670 × 10⁻⁸ W/(m²·K⁴).
What are the units of heat transfer?
Heat transfer rate is in watts (joules per second), BTU/h in US units. Total heat is in joules or BTU.
Sources
- Incropera, F. P. et al., Fundamentals of Heat and Mass Transfer, Wiley.
- Cengel, Y. A. and Ghajar, A. J., Heat and Mass Transfer: Fundamentals and Applications.
- ASHRAE Handbook: Fundamentals, heat transfer.
Last reviewed: November 10, 2026