Orifice Flow Equation

Orifice flow Q = Cd x A x sqrt(2 dP / rho) / sqrt(1 – beta^4). Enter the pipe and orifice diameters, the pressure drop and the fluid density to get the flow rate and the velocity through the hole.

How it works

A restriction in a pipe makes the fluid speed up and its pressure fall. Measuring that pressure drop across a sharp-edged orifice gives the flow rate, which is why the orifice plate is the most common flow meter in industry.

Q = C × Ao × √(2 ΔP ÷ ρ) ÷ √(1 − β⁴)

β = d ÷ D

Ao = π d² ÷ 4

ṁ = ρ Q

SymbolMeaningSI unit
QVolume flow ratem³/s
CDischarge coefficient (about 0.6 for a sharp-edged orifice plate)–
AoArea of the orifice holem²
ΔPPressure drop across the orificePa
ρFluid densitykg/m³
βDiameter ratio, orifice diameter d ÷ pipe diameter D–

The factor 1 ÷ √(1 − β⁴) is the velocity-of-approach factor. It accounts for the fluid already moving in the pipe before the orifice, and it is close to 1 for small holes (β = 0.3 gives 1.004) but grows quickly as β nears 0.75. For a hole discharging into open air or a tank (no pipe), the factor is 1 and the equation reduces to Q = Cd A √(2 ΔP ÷ ρ), with Cd about 0.6 to 0.65 for a sharp edge and up to 0.98 for a well-rounded nozzle.

The formula applies to liquids (and to gases when the pressure drop is a small fraction of the line pressure; for gases at larger drops an expansibility factor ε below 1 multiplies the result). The standard ISO 5167 gives C as a function of β, the pipe Reynolds number and the tap positions, usually 0.595 to 0.62. The Orifice Flow Calculator applies the full standard.

Related: Fluid Mechanics and Pipe Flow guide (flow measurement), Orifice Flow Calculator (ISO 5167 with Reader-Harris/Gallagher), Bernoulli equation. All formulas are listed in the Formulas library.

Worked example

Water through a 50 mm orifice in a 100 mm pipe with a 25 kPa pressure drop: β = 0.5, so the approach factor is 1 ÷ √(1 − 0.0625) = 1.0328. The hole area is π × 0.05² ÷ 4 = 0.001963 m², and √(2 × 25,000 ÷ 998) = 7.078 m/s. With C = 0.61, Q = 0.61 × 0.001963 × 7.078 × 1.0328 = 8.76 L/s (8.74 kg/s, or 31.5 m³/h).

The water leaves the hole at 4.46 m/s. If the pressure drop doubles, the flow rises by only √2, about 41 percent, because Q is proportional to the square root of ΔP. That is why orifice meters lose accuracy at low flow: a 10 percent flow reading needs a 1 percent signal.

Things to know

Q varies with the square root of ΔP, so a meter reads well only over about a 3 to 1 flow range. For wider ranges use two transmitters or another meter type.

The measured ΔP is across the pressure taps, not the permanent pressure loss. The permanent loss after recovery is roughly (1 − β²) ΔP, about 75 percent of the reading at β = 0.5.

Use the actual density at the operating temperature and pressure. For gases the density changes with pressure, so use the upstream density and the expansibility factor, or the full ISO method in the Orifice Flow Calculator.

Common questions

What is the orifice flow equation?

Q = C A √(2 ΔP ÷ ρ) ÷ √(1 − β⁴), the flow through a restriction from the pressure drop, the hole area, the fluid density, the discharge coefficient C and the diameter ratio β.

What is a typical orifice discharge coefficient?

About 0.60 to 0.62 for a sharp-edged orifice plate at high Reynolds numbers; about 0.97 to 0.99 for a smooth venturi or nozzle.

How do you size an orifice?

Rearrange for the hole: d = √(4 Q ÷ (π C √(2 ΔP ÷ ρ))) for a hole with no pipe, then correct for β with the approach factor. Pick β between 0.2 and 0.75 and check the Reynolds number is above 10,000.

How does pressure drop change flow through an orifice?

Flow is proportional to the square root of the pressure drop: four times the ΔP gives twice the flow.

Does the orifice equation work for gas?

Yes for small pressure drops. For larger ones multiply by the expansibility factor ε, which is below 1, and use the upstream density.

Sources

  • ISO 5167-2: Measurement of fluid flow by means of pressure differential devices, Part 2: orifice plates.
  • Crane Technical Paper 410, Flow of Fluids Through Valves, Fittings and Pipe.
  • White, F. M., Fluid Mechanics, McGraw-Hill: flow meters.

Last reviewed: November 10, 2026