Saturated Steam Table by Pressure (1 kPa to 15 MPa)

Saturated steam and water properties by pressure from 1 kPa to 15 MPa: saturation temperature, specific volume, internal energy, enthalpy and entropy.

This saturated steam table by pressure answers the question boiler and steam-line engineers ask: at this pressure, what is the steam temperature? Water at 1 MPa (10 bar) boils at 179.89 °C, at 4 MPa at 250.36 °C, and at the standard atmosphere (101.325 kPa) at 99.97 °C.

It lists 35 pressures from 1 kPa (high vacuum, as in a condenser) to 15 MPa, with the saturation temperature and the properties of saturated liquid (f), dry saturated vapor (g) and their difference (fg). Pressures are absolute, not gauge. The values are computed from the IAPWS Industrial Formulation 1997 (IAPWS-IF97).

The table

35 rows
Pressure (kPa)Saturation temperature (°C)vf (m³/kg)vg (m³/kg)uf (kJ/kg)ug (kJ/kg)hf (kJ/kg)hfg (kJ/kg)hg (kJ/kg)sf (kJ/kg·K)sfg (kJ/kg·K)sg (kJ/kg·K)
16.970.0010001129.1829.32384.529.32484.42513.70.10598.86908.9749
217.500.001001466.99073.42398.973.42459.52532.90.26068.46218.7227
532.880.001005328.186137.82419.8137.82423.02560.80.47637.91778.3939
1045.810.001010314.671191.82437.2191.82392.12583.90.64927.49978.1489
2060.060.00101717.6482251.42456.0251.42357.52608.90.83207.07537.9072
5081.320.00102993.2401340.42483.2340.52304.72645.21.09106.50207.5930
7591.760.00103722.2171384.32496.1384.42278.02662.41.21306.24277.4557
10099.610.00104311.6940417.32505.5417.42257.52674.91.30266.05627.3588
101.32599.970.00104341.6733418.92506.0419.02256.52675.51.30676.04777.3544
150111.350.00105271.1594466.92519.2467.12226.02693.11.43355.78947.2229
200120.210.00106050.88574504.52529.1504.72201.62706.21.53015.59687.1269
250127.410.00106720.71870535.12536.8535.42181.22716.51.60725.44527.0524
300133.530.00107320.60579561.12543.2561.52163.42724.91.67185.31986.9916
400143.610.00108360.46239604.32553.1604.72133.32738.11.77665.11886.8954
500151.840.00109260.37480639.62560.7640.22107.92748.11.86064.96006.8206
600158.830.00110060.31558669.82566.8670.52085.62756.11.93114.82816.7592
800170.410.00111480.24033720.12576.0721.02047.32768.32.04604.61566.6615
1000179.890.00112720.19435761.62582.8762.72014.42777.12.13844.44656.5850
1200187.960.00113850.16325797.12587.9798.51985.32783.82.21634.30546.5217
1400195.050.00114890.14077828.52591.8830.11958.82788.92.28394.18366.4675
1600201.380.00115870.12373856.82594.9858.61934.32792.92.34384.07626.4200
1800207.120.00116790.11036882.52597.3884.61911.42796.02.39783.97986.3776
2000212.380.00117680.099581906.32599.2908.61889.82798.42.44703.89216.3392
2500223.960.00119740.079947959.02602.2962.01840.12802.02.55443.70156.2560
3000233.860.00121670.0666641004.72603.31008.41794.92803.32.64563.54026.1858
3500242.560.00123500.0570581045.52603.01049.81753.02802.72.72543.39916.1245
4000250.360.00125260.0497771082.42601.81087.41713.52800.92.79673.27316.0697
5000263.940.00128640.0394461148.12597.01154.51639.72794.22.92073.05305.9737
6000275.590.00131930.0324491205.82589.91213.71570.82784.63.02742.86265.8901
7000285.830.00135190.0273801258.02580.91267.41505.12772.63.12202.69265.8146
8000295.010.00138470.0235281306.02570.41317.11441.52758.63.20772.53725.7448
9000303.350.00141810.0204931350.92558.41363.71379.22742.93.28662.39245.6790
10000311.000.00145260.0180341393.32545.11407.91317.62725.53.36032.25565.6159
12500327.820.00154610.0135011492.12505.71511.51163.02674.53.52881.93535.4640
15000342.160.00165700.0103401585.32455.81610.21000.72610.93.68441.62645.3108

Source and notes: Computed by Engineer Underground from the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam (IAPWS-IF97, revised release R7-97(2012)), regions 1, 2 and 4. The implementation reproduces the release's own verification values to 8 digits. Reference state: internal energy and entropy are zero for saturated liquid at the triple point (0.01 C). Each row was also checked for h = u + P v and against the Clausius-Clapeyron relation. Values can differ in the fourth or fifth digit from tables built on the IAPWS-95 formulation.

How to use this table

  1. Convert gauge pressure to absolute first: add the atmospheric pressure (about 101.3 kPa or 14.7 psi) to a gauge reading. A reading of 9 bar gauge is about 10 bar absolute.
  2. Read the saturation temperature in the second column. Steam in contact with water at this pressure is at exactly this temperature; above it the steam is superheated.
  3. Use hfg for the heat released when dry steam condenses (the useful heat of process steam), and hg for the total heat content of dry steam above the triple-point liquid.

Worked example: process steam at 10 bar and a condenser at 10 kPa

  • Steam at 1 MPa (10 bar absolute): the saturation temperature is 179.89 °C. Condensing 1 kg of dry saturated steam releases hfg = 2014.4 kJ/kg; a 1,000 kg/h condensing load therefore delivers 560 kW of heat.
  • A steam turbine condenser at 10 kPa absolute condenses at 45.81 °C, which is why cooling water near 25 °C can sustain a deep vacuum. Steam at 4 MPa condenses at 250.36 °C; its specific volume (vg = 0.049777 m³/kg) is 295 times smaller than at 10 kPa (14.671 m³/kg), which is why low-pressure turbine blades are so long.

Notes and cautions

  • Pressures in the first column are absolute. A vacuum gauge reads below atmospheric; a pressure gauge reads above it. Convert before using the table.
  • The saturation temperature is a property of pressure alone. A steam trap works by discharging condensate at or just below this temperature.
  • Heat content (enthalpy) values depend on the reference state, here the saturated liquid at the triple point. Use differences between states, not absolute values, when you mix tables from different sources.
  • The table stops at 15 MPa, inside the range of the IAPWS-IF97 equations for liquid water and steam on the saturation line (up to 16.5 MPa and 350 °C). The critical pressure of water is 22.064 MPa; above it water has no boiling point.
  • IAPWS-IF97 agrees with the scientific IAPWS-95 formulation to within a few hundredths of a percent here, so a textbook table can differ from this one in the fourth or fifth digit (for example 179.89 against 179.88 °C at 1 MPa).

FAQ

What is the temperature of steam at 1 bar?

Saturated steam at 100 kPa (1 bar absolute) is at 99.61 °C. At the standard atmosphere, 101.325 kPa, it is 99.97 °C.

What is the temperature of steam at 10 bar?

179.89 °C for saturated steam at 1 MPa (10 bar absolute), the pressure of a typical medium-pressure process steam line.

What is the temperature of steam at 150 psi?

About 186 °C for 150 psig (gauge), because that is 164.7 psia or 1.136 MPa absolute, and about 181 °C for 150 psia. Convert to kPa and read the table, interpolating between 1,000 and 1,200 kPa.

What is the difference between this and the superheated table?

This table is for water and steam at the boiling point. If the steam is hotter than the saturation temperature for its pressure, use the Superheated Steam Table.

How do I convert between steam pressure units?

One MPa is 10 bar, 1,000 kPa or 145.04 psi. One psi is 6.895 kPa. The Pressure Converter on this site does it exactly.

Sources

  • IAPWS, Revised Release on the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam, R7-97(2012). Publication in whole or in part is allowed with attribution to the International Association for the Properties of Water and Steam.
  • Wagner, W. et al., “The IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam”, J. Eng. Gas Turbines Power 122 (2000) 150-182.
  • Cengel, Y. A. and Boles, M. A., Thermodynamics: An Engineering Approach, McGraw-Hill: steam tables (for comparison; tables built on the IAPWS-95 formulation can differ in the fourth or fifth digit).
  • Computed by Engineer Underground from the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam (IAPWS-IF97, revised release R7-97(2012)), regions 1, 2 and 4. The implementation reproduces the release's own verification values to 8 digits. Reference state: internal energy and entropy are zero for saturated liquid at the triple point (0.01 C). Each row was also checked for h = u + P v and against the Clausius-Clapeyron relation. Values can differ in the fourth or fifth digit from tables built on the IAPWS-95 formulation.

Published by Nick Peterson, mechanical engineer.