Methods and Sources for the Reference Tables
Where each table’s numbers come from, and which tables have been rechecked a second way.
Every reference table on this site has a note saying where its numbers come from. This page gathers those notes in one place, grouped by topic, and says which tables have also been rechecked by a second, independent method. It supports the summary on How We Write and Check Our Pages.
Where a value follows from a definition or a standard equation, the table is computed rather than copied. Where a value is a published figure (for example a standard size), the note names the standard. The last column is deliberately modest: only the tables we have actually rechecked are marked, and the rest say so. If you spot an error, please report it.
There are 89 tables in the list, and 59 of them have been rechecked by a second method. The second round of rechecks (November 2026) found and corrected two errors: the lb/in³ column of the metals density table and the percent IACS column of the resistivity table.
Computing and general
| Table | Where the numbers come from | Second-method recheck |
|---|---|---|
| Physical Constants | CODATA 2018 recommended values (NIST, Tiesinga et al., 2021) and the 2019 redefinition of the SI, which fixed c, h, e, k and N_A exactly. Newer CODATA releases change only the last digits of the measured constants. | Not yet rechecked by a second method; see the source. |
| Greek Alphabet in Engineering | The 24 letters of the modern Greek alphabet. Uses are the common conventions in mechanics, heat transfer, electrical engineering and statistics; meanings differ between fields and authors, so always define a symbol where you first use it. | Not yet rechecked by a second method; see the source. |
| ASCII Table | ANSI X3.4 / ISO 646 (ASCII); the first 128 code points of Unicode and UTF-8. | Not yet rechecked by a second method; see the source. |
| SI Prefixes (Quetta to Quecto) | SI Brochure, 9th edition (BIPM); quetta, ronna, ronto and quecto were added in 2022. | Not yet rechecked by a second method; see the source. |
| Drawing Sheet Sizes (ISO A, ANSI and ARCH) | ISO 216 and ISO 5457 (A series trimmed sheets), ASME Y14.1 (ANSI A to E decimal inch drawing sheets) and the customary US architectural sizes. Conversions use 25.4 mm per inch exactly. | Area and aspect ratio recomputed from the millimeter size; inches from millimeters. |
| Renard Preferred Numbers (R5, R10, R20 and R40) | ISO 3, Preferred numbers: series of preferred numbers. Each step multiplies by 10^(1/N) (R5 1.585, R10 1.259, R20 1.122, R40 1.059); the preferred values are the rounded results. R40 lists every step, R20 every second step, R10 every fourth and R5 every eighth. Multiply or divide by powers of ten for other decades. | Rounded values compared with 10^(n/40): error at most 1.3 percent. |
| Trigonometry Table (Sine, Cosine, Tangent) | Computed from the definitions. sin θ = cos(90° − θ); tan θ = sin θ ÷ cos θ; cot θ = 1 ÷ tan θ. Exact values: sin 30° = 0.5, sin 45° = √2 ÷ 2 = 0.70711, sin 60° = √3 ÷ 2 = 0.86603. For angles above 90° use the reduction rules (sin(180° − θ) = sin θ, cos(180° − θ) = −cos θ). | sin² + cos² = 1 checked in every row. |
| Speed Conversion Chart (mph, km/h, m/s, knots) | Exact factors: 1 mph = 0.44704 m/s; 1 km/h = 1 ÷ 3.6 m/s; 1 ft/s = 0.3048 m/s; 1 knot = 1,852 m per hour = 0.514444 m/s. Mach is shown at the speed of sound in standard air at sea level (340.29 m/s); the real value depends on temperature. | Every column recomputed from mph by definition (1.609344 km/mi, 0.44704 m/s, 1.466667 ft/s, 0.868976 kn). |
| G-Code and M-Code List (CNC Reference) | ISO 6983 and the NIST RS274NGC interpreter for the common meanings; Fanuc-style conventions for the canned cycles. Controls differ, especially for M codes, lathe codes and codes above G100: the machine manual is the authority. | Not yet rechecked by a second method; see the source. |
Electrical and electronics
| Table | Where the numbers come from | Second-method recheck |
|---|---|---|
| Motor Full-Load Current (Three-Phase) | Full-load currents of three-phase AC induction motors as listed in NFPA 70 (National Electrical Code), Table 430.250. The code values are for sizing wiring and protection; a nameplate gives the real figure for a given motor. The last column is computed: kW out / (sqrt(3) x 460 V x listed current), which shows the table assumes a combined efficiency and power factor of about 0.45 for small motors rising to about 0.75 for 100 hp, so the code figures are on the high side of a modern motor. 1 hp = 0.7457 kW. | Not yet rechecked by a second method; see the source. |
| Standard Breaker and Fuse Sizes | Standard ampere ratings of fuses and circuit breakers in NFPA 70 (National Electrical Code) Section 240.6(A); fuses are also made in 1, 3, 6, 10, 601 A and other special ratings. IEC miniature breakers use 6, 10, 13, 16, 20, 25, 32, 40, 50, 63, 80, 100 and 125 A. Columns are computed: the 80 percent rule (continuous loads on a standard breaker) and power = sqrt(3) x V x I (three-phase) or V x I. | 80 percent load and the 400 V three-phase and 120 V single-phase powers recomputed. |
| IP Ratings Explained | IEC 60529, Degrees of protection provided by enclosures (IP code). The first digit is protection against solid objects and dust, the second against water; an X replaces a digit that was not tested, and the digits do not imply each other: IP67 does not mean IP65. For the closest NEMA equivalents (NEMA 250): NEMA 3R is about IP14, NEMA 4 and 4X about IP66, NEMA 12 about IP52, NEMA 6P about IP68, but NEMA also tests corrosion and icing. | Not yet rechecked by a second method; see the source. |
| AWG Wire Gauge Table | ASTM B258: d = 0.127 mm x 92^((36 – n) / 39). Copper resistivity 1.7241e-8 ohm m, density 8,960 kg/m3. | Diameters compared with published AWG values. |
| Resistivity of Metals and Alloys | Typical handbook values at 20 C (CRC Handbook). 100 percent IACS = 58.0 MS/m (1.724e-8 ohm m). Alloys vary with composition. | Conductivity recomputed as 1 ÷ resistivity and percent IACS against 58.0 MS/m. This recheck found the percent IACS column showing MS/m instead; corrected November 13, 2026. |
| E-Series Preferred Values (E6, E12, E24, E96) | IEC 60063 preferred number series. The tolerances shown are the usual ones for resistors of that series. | Not yet rechecked by a second method; see the source. |
| Resistor Color Code Chart | IEC 60062, Marking codes for resistors and capacitors. Four-band resistors read two digits, a multiplier and a tolerance; five-band resistors read three digits, a multiplier and a tolerance; six-band resistors add a temperature coefficient. The temperature coefficient bands in common use are brown 100, red 50, orange 15, yellow 25, blue 10 and violet 5 ppm/K. | Tolerance and temperature coefficient bands compared with published color code tables. |
| Decibel Conversion Chart (dB to Power and Voltage Ratio) | Definitions: dB = 10 log₁₀(P₂ ÷ P₁) = 20 log₁₀(V₂ ÷ V₁), the voltage form holding for equal impedances. +3 dB is very nearly double the power and −3 dB half; +6 dB is nearly double the voltage; +10 dB is ten times the power; +20 dB is ten times the voltage. | Ratios checked against the definitions. |
| AWG to mm2 Conversion Chart (Wire Size to Metric) | AWG diameters follow d = 0.127 mm × 92^((36 − n) ÷ 39) (n = 36 for AWG 36; 0000 is n = −3). Circular mils are the diameter in mils squared. The nearest metric size is the standard IEC 60228 cross-section (0.5 to 300 mm²) closest in area; the nearest size is a guide only, and ampacity and voltage-drop rules differ between AWG (NEC) and metric (IEC) practice. Resistance uses copper at 1.724 × 10⁻⁸ Ω m. | Diameters and areas compared with published AWG values. |
Fasteners and threads
| Table | Where the numbers come from | Second-method recheck |
|---|---|---|
| Metric Thread Table (Coarse) | ISO 261 and ISO 724 (coarse series); d2 = d – 0.64952 P, d3 = d – 1.22687 P, At = pi/4 (d – 0.9382 P)2 (ISO 898-1). Tap drill is d – P, rounded to a stock size in practice. | Pitch and minor diameters recomputed from the ISO 68-1 basic profile (d − 0.649519 P, d − 1.226869 P); tap drills within 0.06 mm of d − P. |
| Metric Fine Thread Table | ISO 261 and ISO 724 (selected fine pitches), same formulas as the coarse table. | Pitch and minor diameters recomputed from the ISO 68-1 basic profile (d − 0.649519 P, d − 1.226869 P); tap drills within 0.06 mm of d − P. |
| UNC and UNF Thread Chart (Unified Inch Thread Sizes) | ASME B1.1 (Unified inch threads): d2 = d – 0.6495/n, d3 = d – 1.0825/n, At = 0.7854 (d – 0.9743/n)2. Tap drill: choose the nearest stock drill. | Pitch, pitch diameter and minor diameter recomputed from the basic Unified profile (p = 1/n, D − 0.649519 p, D − 1.082532 p). |
| Inch Fraction to Decimal and Millimeter Chart | 1 inch = 25.4 mm exactly. | Every fraction recomputed exactly and converted at 25.4 mm per inch. |
| Bolt Strength Grades and Property Classes | ISO 898-1 (minimum values for carbon and alloy steel bolts, screws and studs; yield is the 0.2 percent proof stress, or the lower yield for classes 4.6 to 5.6), SAE J429 and ASTM A307 (minimum values in ksi). The MPa and ksi columns are converted from the standard values (1 ksi = 6.894757 MPa). Class 4.8 and 5.8 yield values are minimums for the whole size range; check the standard for the exact limits by size. | Not yet rechecked by a second method; see the source. |
| Estimated Bolt Tightening Torque (Metric) | Computed: preload F = 0.75 x proof strength x stress area (proof strength from ISO 898-1: 580 MPa for class 8.8 up to M16 and 600 MPa above, 830 MPa for 10.9, 970 MPa for 12.9); torque T = K x F x d with K = 0.20 for dry plain steel threads and K = 0.15 for lightly oiled threads. K varies from about 0.1 to 0.3 with plating, lubricant and finish, so these are estimates: use the figure on the drawing or in the maker's data where there is one. | Torques recomputed from preload with T = K F d (K 0.20 dry, 0.15 lubricated). |
| Metric Hex Bolt, Nut and Washer Dimensions | ISO 4017 (hex head bolts, product grade A and B), ISO 4032 (hex nuts, style 1) and ISO 7089 (plain washers, normal series). Dimensions are nominal. DIN 931 and DIN 933 bolts and DIN 934 nuts use larger flats for M10 (17 mm), M12 (19 mm), M14 (22 mm) and M22; the ISO flats are listed. | Across-flats inch column recomputed from millimeters. |
| Socket Head Cap Screw Dimensions | ISO 4762 (hexagon socket head cap screws), maximum head diameter and nominal head height (equal to the thread diameter). Counterbore sizes are a practical rule: the head diameter plus 0.5 mm, and a depth of the head height plus 0.5 mm; the standard recommends sizes by series, so check it for tight fits. | Not yet rechecked by a second method; see the source. |
| Metric Bolt Clearance Hole Sizes | ISO 273, through holes for bolts and screws: fine series (close fit, accurate positions), medium series (normal fit, the usual choice) and coarse series (loose fit, rough work). The tap drill is the diameter minus the coarse pitch (about 75 percent thread). | Clearance in the medium hole recomputed as hole − nominal diameter. |
| Wrench and Socket Size Chart (Metric to SAE Inch) | ISO 4017 and ISO 4032 for metric bolts and nuts (DIN 931, 933 and 934 use larger flats for M10, M12 and M14), ASME B18.2.1 for inch hex bolts and cap screws. The wrench size is the across-flats dimension. | Not yet rechecked by a second method; see the source. |
| Drill Bit Size Chart (Fractional, Number, Letter and Metric) | Number and letter drill diameters from the standard drill size lists (ANSI B94.11M and manufacturer catalogs); fractions are exact; metric sizes follow ISO 235 steps; 1 inch = 25.4 mm exactly. | Millimeter column recomputed from the inch column (25.4 mm per inch). |
| NPT Pipe Thread Chart (Dimensions, TPI and Tap Drill Sizes) | ASME B1.20.1, Pipe Threads, General Purpose (Inch). Pitch diameter E0 = D – (0.05 D + 1.1) / n, effective length L2 = (0.8 D + 6.8) / n and thread height 0.8 / n are worked out from the standard formulas; L1 and the tap drills are the usual published values (drill before reaming or pipe tapping). | Pitch recomputed as 1 ÷ threads per inch and thread height as 0.8 p. |
| Acme Thread Chart (Dimensions, Pitch and Lead Angle) | ASME B1.5, Acme Screw Threads: preferred General Purpose diameter and pitch series. Basic dimensions computed from the standard relations: thread height 0.5 P, pitch diameter D – 0.5 P, minor diameter D – P, crest flat 0.3707 P, thread angle 29 degrees. Values are basic sizes before allowances and tolerances. | Pitch, pitch diameter (D − p/2) and minor diameter (D − p) recomputed from the general-purpose Acme basic form. |
| Nail Size Chart (Penny Sizes, Length and Diameter) | ASTM F1667, Standard Specification for Driven Fasteners: common wire nails. Box, sinker and finish nails of the same penny size have thinner shanks. Millimeter values are converted from the inch sizes. | Millimeter length and diameter recomputed from inches. |
Fluids, pipes and air
| Table | Where the numbers come from | Second-method recheck |
|---|---|---|
| Properties of Air vs Temperature | Dry air at 101.325 kPa. Density from the ideal gas law (R = 287.05 J/kg K); viscosity from Sutherland's law (reference 17.16 micropascal seconds at 273.15 K, S = 110.4 K); specific heat and conductivity interpolated from standard tables (Cengel and Ghajar, Appendix, air at 1 atm); Prandtl number = cp x viscosity / conductivity; speed of sound = sqrt(1.4 R T). Humid air is slightly lighter. | Kinematic viscosity recomputed as μ ÷ ρ, density from the ideal gas law at 1 atm, Prandtl number as μ cp ÷ k. |
| Properties of Common Gases | Molar masses and typical gas properties at 20 C and 101.325 kPa (standard tables: Cengel and Ghajar, Appendix; CRC Handbook). Calculated: R = 8,314.46 / M, density = P / (R T), kinematic viscosity = dynamic viscosity / density, speed of sound = sqrt(gamma R T). Values for gamma and viscosity are typical and vary a little with temperature. | Gas constant recomputed as 8,314.46 ÷ M and density at 20 °C, 1 atm from the ideal gas law. |
| Properties of Common Liquids | Typical values at about 20 C (CRC Handbook, Cengel and Ghajar Appendix, supplier data sheets). Fuels and mixtures vary with grade and composition (gasoline, diesel); viscosity changes strongly with temperature. Calculated: kinematic viscosity = dynamic viscosity / density; specific gravity = density / 998.2. | Kinematic viscosity recomputed as dynamic viscosity ÷ density. |
| Pipe Roughness Values | Absolute roughness of commercial pipe (Moody, 1944; Crane TP-410; Cengel and Cimbala, Fluid Mechanics, Table 8-2). The typical value is the geometric mean of the range; relative roughness = roughness / inside diameter. Old pipe is much rougher than new: corrosion and deposits can raise the roughness several times. | Inch roughness and relative roughness for 50, 100 and 200 mm pipes recomputed from the typical roughness. |
| Fitting and Valve Loss Coefficients (K Factors) | Typical loss coefficients for turbulent flow (Cengel and Cimbala, Fluid Mechanics, Table 8-4; Crane TP-410). The pressure loss is K x (density x velocity squared / 2); the head loss is K x velocity squared / (2 g). The equivalent length is K divided by a typical friction factor of 0.02 (fully rough flow in medium pipe); makers' data for the exact valve is always better. | Not yet rechecked by a second method; see the source. |
| Pipe Schedule 40 and 80 Dimensions Chart (NPS and DN) | ASME B36.10M (carbon steel pipe), B36.19M for stainless. Inside diameter, flow area and mass (7,850 kg/m3) are computed from the OD and wall. | Inside diameter recomputed as OD − 2 × wall. |
| Water Properties vs Temperature | Liquid water near atmospheric pressure, typical handbook values (CRC Handbook, IAPWS). Vapor pressure from the Hyland-Wexler equation. | Kinematic viscosity recomputed as dynamic viscosity ÷ density. |
| Standard Atmosphere Table (ISA) | ICAO / ISO 2533 standard atmosphere: sea level 288.15 K, 101,325 Pa, lapse rate 6.5 K per km to 11 km, isothermal 216.65 K above. | Recomputed from the ISA definition (lapse rate 6.5 K/km to 11 km, then isothermal; p0,101.325 kPa, R 287.053, g 9.80665). |
| Density of Water vs Temperature (kg/m³, lb/ft³, lb/gal) | Kell, G. S., Density, thermal expansivity and compressibility of liquid water from 0 to 150 °C, J. Chem. Eng. Data 20 (1975), for air-free water at 1 atm. Specific weight uses g = 9.80665 m/s²; 1 kg/m³ = 0.0624280 lb/ft³ = 0.0083454 lb/US gal. | Unit columns recomputed from kg/m³ (lb/ft³ × 16.0185, lb/gal × 119.826, specific weight × g). |
| Viscosity of Water vs Temperature (Dynamic and Kinematic) | Handbook values every 10 °C (CRC Handbook, IAPWS) for liquid water at about 1 atm; values at 5 °C, 15 °C and so on are interpolated (about 0.3 percent, following the exponential trend). Kinematic viscosity = dynamic viscosity ÷ density (Kell). 1 Pa·s = 0.671969 lb/ft·s; 1 m²/s = 10.7639 ft²/s. | Unit columns recomputed from the mPa·s and density-based kinematic values (lb/ft·s = Pa·s × 0.671969). |
| Vapor Pressure of Water vs Temperature (Saturation Pressure) | Hyland, R. W. and Wexler, A., Formulations for the thermodynamic properties of the saturated phases of H2O, ASHRAE Transactions 89(2A), 1983 (0 to 200 °C); agrees with the IAPWS steam tables to better than 0.1 percent. 1 mmHg = 133.322 Pa, 1 inHg = 3386.389 Pa. | Not yet rechecked by a second method; see the source. |
| Boiling Point of Water vs Pressure and Altitude | The temperature at which the vapor pressure (Hyland-Wexler equation) equals the pressure. Pressure at altitude from the International Standard Atmosphere, p = 101,325 (1 − 2.25577×10⁻⁵ h)^5.25588 Pa; the weather and the actual local pressure shift the values by up to about 1 °C. | Not yet rechecked by a second method; see the source. |
| Speed of Sound in Air vs Temperature | Computed for dry air as an ideal gas, c = sqrt(gamma R T) with gamma = 1.4 and R = 287.05 J/(kg K), which gives 331.3 m/s at 0 C and 343.2 m/s at 20 C (the standard-atmosphere value at 15 C is 340.3 m/s). Humidity raises the speed by up to about 0.5 percent at 30 C. | Speed of sound recomputed as √(γ R T) with γ 1.4 and R 287.05, and the unit columns from m/s. |
| Copper Tube Sizes Chart (Type K, L and M) | ASTM B88, Standard Specification for Seamless Copper Water Tube (nominal or standard sizes): the outside diameter is always 1/8 inch more than the nominal size. Inside diameter and contents are computed from the outside diameter and the Type L wall. Verify critical dimensions against the current standard or the tube maker. | Millimeter OD, Type L inside diameter (OD − 2 t) and water held per foot recomputed. |
Heat and energy
| Table | Where the numbers come from | Second-method recheck |
|---|---|---|
| Thermal Conductivity of Materials | Typical values near room temperature (Cengel and Ghajar, Heat and Mass Transfer, Appendix; ASHRAE Handbook, Fundamentals; supplier data). Alloys and plastics vary with composition, and insulation and wood vary with density and moisture. Thermal diffusivity = k / (density x specific heat); 1 W/m K = 0.577789 BTU/h ft F. | Thermal diffusivity recomputed as k ÷ (ρ c) and the BTU column at 0.577789 per W/m·K. |
| Emissivity of Common Surfaces | Typical total hemispherical emissivity near room temperature (Cengel and Ghajar, Heat and Mass Transfer, Table A-18; ASHRAE Handbook, Fundamentals). Emissivity depends strongly on finish, oxidation and temperature, so a polished metal can read many times lower than the same metal oxidized. Radiation emitted = emissivity x 5.670374419E-8 x T^4 (T = 373.15 K), without the surroundings. | Reflectivity recomputed as 1 − ε and emitted radiation at 100 °C as ε σ T⁴. |
| Specific Heat of Water vs Temperature (J/kg·K, Btu/lb·°F) | Handbook values every 10 °C (CRC Handbook, IAPWS) for liquid water at about 1 atm; values at 5 °C, 15 °C and so on are interpolated (about 0.1 percent). 1 Btu/lb·°F = 4.1868 kJ/kg·K (International Table), 1 cal/g·°C = 4.184 kJ/kg·K (thermochemical). | Not yet rechecked by a second method; see the source. |
| Universal Gas Constant (R) in Every Unit | R = N_A k_B = 8.31446261815324 J/(mol K), exact (2019 SI redefinition; CODATA 2018); other units converted with exact definitions: 1 atm = 101,325 Pa, 1 cal = 4.184 J, 1 lb-mol = 453.59237 mol, 1 °R = 5/9 K, International Table Btu = 1055.05585262 J. | Not yet rechecked by a second method; see the source. |
| Saturated Steam Table by Temperature (0 to 350 °C) | Computed by Engineer Underground from the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam (IAPWS-IF97, revised release R7-97(2012)), regions 1, 2 and 4. The implementation reproduces the release's own verification values to 8 digits. Reference state: internal energy and entropy are zero for saturated liquid at the triple point (0.01 C). Each row was also checked for h = u + P v and against the Clausius-Clapeyron relation. Values can differ in the fourth or fifth digit from tables built on the IAPWS-95 formulation. | Not yet rechecked by a second method; see the source. |
| Saturated Steam Table by Pressure (1 kPa to 15 MPa) | Computed by Engineer Underground from the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam (IAPWS-IF97, revised release R7-97(2012)), regions 1, 2 and 4. The implementation reproduces the release's own verification values to 8 digits. Reference state: internal energy and entropy are zero for saturated liquid at the triple point (0.01 C). Each row was also checked for h = u + P v and against the Clausius-Clapeyron relation. Values can differ in the fourth or fifth digit from tables built on the IAPWS-95 formulation. | Not yet rechecked by a second method; see the source. |
| Superheated Steam Table (Specific Volume, Enthalpy, Entropy) | Computed by Engineer Underground from the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam (IAPWS-IF97, revised release R7-97(2012)), regions 1, 2 and 4. The implementation reproduces the release's own verification values to 8 digits. Reference state: internal energy and entropy are zero for saturated liquid at the triple point (0.01 C). Each row was also checked for h = u + P v and against the Clausius-Clapeyron relation. Values can differ in the fourth or fifth digit from tables built on the IAPWS-95 formulation. | Not yet rechecked by a second method; see the source. |
| Coefficient of Thermal Expansion Table (Metals, Glass, Plastics) | Typical linear coefficients of thermal expansion at about 20 to 100 C (ASM Handbook; CRC Handbook of Chemistry and Physics; Machinery's Handbook). Plastic and wood values vary with grade, fill and direction. The per-degree-Fahrenheit column is the SI value divided by 1.8; the growth columns are alpha times the length times the temperature change. | Per-°F values (÷ 1.8) and the two growth columns recomputed from α. |
| Standard Conditions: STP, NTP and SATP (Temperature and Pressure) | Definitions from IUPAC (1982 recommendation), NIST, ISO 13443 and the US gas industry. Molar volume is R T / P with R = 8.314462618 J/(mol K); dry air density is P M / (R T) with M = 28.9647 g/mol. Always state the reference conditions when you quote a gas volume or flow rate. | Kelvin, psia and ideal-gas molar volume (R T ÷ p) recomputed. |
| Dew Point Chart (Temperature and Relative Humidity) | Computed with the Magnus formula: γ = ln(RH ÷ 100) + 17.62 T ÷ (243.12 + T), dew point = 243.12 γ ÷ (17.62 − γ), with T in °C (Sonntag constants, accurate to about 0.35 °C between −45 and 60 °C). The psychrometric calculator on this site uses the more exact Hyland-Wexler equations; results agree to a few tenths of a degree. | Compared with the Buck vapor pressure equation: largest difference 0.09 °C. |
| Temperature Conversion Chart (Celsius, Fahrenheit, Kelvin) | Exact definitions: °F = °C × 9 ÷ 5 + 32; K = °C + 273.15; °R = K × 9 ÷ 5. To convert a temperature difference, use the factor 9 ÷ 5 only (a change of 10 °C is a change of 18 °F), without the 32. | Fixed points checked (0, 100, −40). |
| Pressure Conversion Chart (psi, bar, kPa, MPa, atm) | Exact factors: 1 psi = 6,894.757 Pa (from the pound-force and the inch); 1 bar = 100,000 Pa; 1 kgf/cm² = 98,066.5 Pa; 1 atm = 101,325 Pa; 1 mmHg = 133.3224 Pa. Values are gauge or absolute according to how you read the psi; the conversion does not change that. | Factors compared with NIST values. |
| Power Conversion Chart (hp, kW, BTU/h, Tons) | Exact factors: 1 hp (mechanical, 550 ft lbf/s) = 745.6999 W; 1 PS (metric hp) = 735.49875 W; 1 BTU/h (International Table) = 0.29307107 W; 1 ton of refrigeration = 12,000 BTU/h = 3,516.85 W. Electrical horsepower is defined as exactly 746 W, 0.04 percent more than the mechanical horsepower. | Factors compared with NIST values. |
| Flow Rate Conversion Chart (gpm, L/min, m3/h, cfm) | Exact factors: 1 US gallon = 3.785411784 L; 1 ft³ = 28.316846592 L; 1 m³ = 1,000 L. The imperial (UK) gallon is 4.54609 L, about 20 percent larger than the US gallon, so check which gallon a flow rating uses. Liquids use gpm and L/min; air and gas flows are usually cfm, with the pressure and temperature stated. | Factors compared with NIST values. |
Materials and mechanical parts
| Table | Where the numbers come from | Second-method recheck |
|---|---|---|
| Steel Grade Cross Reference | Closest equivalents from AISI/SAE, ASTM/SAE UNS, EN 10027 and JIS designations as given in common cross-reference tables. Grades from different standards are never identical (limits on carbon, manganese, sulfur and residuals differ), so treat a match as "very similar", and check the specification before substituting. "About" marks a looser match. | Not yet rechecked by a second method; see the source. |
| Aluminum Alloys and Tempers | Typical room-temperature values for the named temper (ASM Handbook, Aluminum Association "Aluminum Standards and Data"; minimums in the standards are lower). Temper codes: H = work hardened, T6 = solution heat treated and artificially aged, T3 = solution treated and cold worked. Density in kg/m3; the ksi columns are converted from MPa. | Not yet rechecked by a second method; see the source. |
| Stainless Steel Grades | Nominal compositions and minimum annealed plate properties from ASTM A240 / A240M (ksi converted from MPa). Corrosion ratings are qualitative. Cold working raises the strength of austenitic grades well above the annealed minimums; the grades marked L are low in carbon so they resist sensitization after welding. | Not yet rechecked by a second method; see the source. |
| Metric Parallel Keys and Keyways | ISO 773 and DIN 6885 sheet 1 (parallel keys, form A, normal fit). The key length is chosen from the standard length series to carry the torque: see the shaft and key sizing calculator. | Key cross-section recomputed as b × h. |
| Inch Square Keys and Keyseats | ANSI B17.1 (keys and keyseats), square keys: the key width equals the height, the shaft keyway is half the key height deep, and the hub keyway takes the other half. Rectangular keys are used where a square key would be too tall for the shaft. | Decimal and metric key sizes recomputed from the fraction; shaft keyway depth as half the key. |
| O-Ring Cross-Sections and Groove Depths | AS568 standard cross-sections (the dash number sets the cross-section and the inside diameter; 1.78, 2.62, 3.53, 5.33 and 6.99 mm are the metric equivalents of the 0xx to 4xx series) and the other common metric sizes. Groove depths are computed from the usual squeeze guidance (static 15 to 30 percent, dynamic 10 to 20 percent of the cross-section); the groove width, the gland fill and the fluid, temperature and pressure change the final design, so use the seal maker's gland tables. | Not yet rechecked by a second method; see the source. |
| Deep-Groove Ball Bearing Dimensions | ISO 15 boundary dimensions of single-row deep-groove ball bearings, 60, 62 and 63 series (bore codes 00 to 12 map to 10, 12, 15, 17 mm and then 5 x the code). Load ratings depend on the maker: see the catalog. | Mean diameter recomputed as (d + D) / 2. |
| Sheet Steel Gauge Chart | Manufacturers' Standard Gauge for uncoated carbon steel sheet (gauge systems for aluminum, stainless and galvanized sheet differ). Mass uses 7,850 kg/m3. | Millimeters from inches and sheet mass at 7,850 kg/m³ (lb/ft² at 0.204816 per kg/m²). |
| Lewis Form Factor Table (Y for Spur Gear Teeth) | Y for 20 degree full-depth involute teeth as tabulated in Shigley and Mischke, Mechanical Engineering Design (McGraw-Hill); y is Y divided by pi; the last column is Y divided by the rack value 0.485. | Second column recomputed as Y ÷ π. |
| Coefficient of Friction Table (Static and Kinetic) | Typical values for clean, dry surfaces unless stated, as tabulated in physics and mechanical design texts (for example Serway and Jewett, Physics for Scientists and Engineers; Marks' Standard Handbook for Mechanical Engineers). Real values vary widely with finish, contamination, temperature, speed and load; use measured values for design. | Not yet rechecked by a second method; see the source. |
| Young's Modulus Table (Modulus of Elasticity, Shear Modulus, Poisson's Ratio) | Typical room-temperature values from ASM Handbook, Machinery's Handbook and Shigley's Mechanical Engineering Design. Alloys and heat treatment change E by a few percent; plastics, composites and concrete vary widely. E in million psi is E in GPa divided by 6.894757. | E in million psi recomputed from GPa (÷ 6.894757). |
| Density and Specific Heat of Metals Table | Typical values at about 20 C from the CRC Handbook of Chemistry and Physics, ASM Handbook and Incropera, Fundamentals of Heat and Mass Transfer. Alloys vary with composition and temper; steel and stainless melt over a range, so a typical value is given. lb/in3 is kg/m3 times 3.6127e-5; BTU/(lb F) is J/(kg K) divided by 4186.8. | lb/in³ recomputed from kg/m³ (÷ 27,679.9) and BTU/lb·°F from J/kg·K (÷ 4,186.8). This recheck found the lb/in³ column 1,000 times too large; corrected November 13, 2026. |
| Speed of Sound in Common Materials (Water, Steel, Aluminum, Glass) | Typical values at 20 C from the CRC Handbook of Chemistry and Physics and Kinsler et al., Fundamentals of Acoustics. For solids the longitudinal (compression) wave speed in a bar-sized sample is the main value; shear waves travel at about half that speed. Alloy, temperature and pressure change the values. | Not yet rechecked by a second method; see the source. |
| Galvanic Corrosion Chart (Anodic Index and Compatible Metals) | Anodic index values from MIL-STD-889 (Dissimilar Metals), measured in seawater against gold. The potential difference between two metals is the difference of their anodic indices; the metal with the larger index is the anode and corrodes. A common rule is to keep the difference below 0.25 V in a benign indoor environment and below about 0.15 V outdoors or in marine service. | Not yet rechecked by a second method; see the source. |
| Hardness Conversion Chart (Rockwell C, Vickers, Brinell) | Approximate conversion for non-austenitic steels after ASTM E140 (Standard Hardness Conversion Tables for Metals), rounded. Tensile strength is estimated as 3.45 times the Brinell number in MPa, which is accurate to roughly 10 percent for carbon and low-alloy steels and does not apply to austenitic stainless steel, cast iron or non-ferrous metals. Conversions between scales are approximate: measure in the scale that the specification asks for. | Not yet rechecked by a second method; see the source. |
| Surface Roughness Conversion Chart (Ra, Rz, N Grades) | ISO 1302 roughness grade numbers N1 to N12 and their preferred Ra values; microinch values are the customary ASME B46.1 equivalents (1 µm = 39.37 µin, rounded to the preferred series). Rz is shown as a range of about 4 to 7 times Ra: there is no exact conversion. Typical processes are indicative. | Not yet rechecked by a second method; see the source. |
| Gear Module and Diametral Pitch Chart | ISO 54, Cylindrical gears for general engineering and for heavy engineering: modules. The values from 1 mm up are the preferred (first-choice) series; 0.5, 0.6 and 0.8 mm are common fine-pitch sizes added for small gears. A less-preferred second series (1.125, 1.375, 1.75, 2.25 mm and so on) exists and should be avoided where possible; check the current standard for the full lists. Diametral pitch P = 25.4 ÷ m; circular pitch p = π m; standard 20° full-depth teeth with addendum m, dedendum 1.25 m and whole depth 2.25 m; pitch diameter d = m z. All computed from the module. | Diametral pitch (25.4/m), circular pitch (π m), addendum (m), dedendum (1.25 m) and whole depth (2.25 m) recomputed. |
| O-Ring Groove Design Chart (Depth, Width and Squeeze) | Rules of thumb computed from the cross-section: static seals are squeezed about 15 to 30 percent (20 percent shown) in a groove about 1.3 to 1.5 times the cross-section wide; dynamic seals about 8 to 16 percent (12 percent shown) in a groove about 1.4 times wide. These are typical starting values: the O-ring maker’s gland tables (for example for AS568 and ISO 3601 sizes) and the pressure, fluid, temperature and material govern the final design. The last two columns give the amount of squeeze, in millimeters, at 15 and 30 percent of the cross-section. | Not yet rechecked by a second method; see the source. |
| Torque Conversion Chart (N m, lbf ft, lbf in, kgf m) | Exact factors: 1 lbf ft = 1.3558179 N m; 1 lbf in = 0.11298483 N m; 1 kgf m = 9.80665 N m; 1 ozf in = 0.0070615518 N m. Torque (a force times a distance) is not the same as energy, though both are measured in newton meters: say "torque" for a turning effort. | Factors compared with NIST values. |
Steel sections and bar
| Table | Where the numbers come from | Second-method recheck |
|---|---|---|
| European I-Beam and H-Beam Sections (IPE, HEA, HEB) | Nominal dimensions of IPE (EN 10365), HE A and HE B (EN 10365, EN 10034) sections. Area, mass (7,850 kg/m3), second moments, section moduli (elastic) and radii of gyration are computed here from the dimensions, including the root fillets; the results agree with the maker's tables to within rounding (for example IPE 200: 28.5 cm2, 22.4 kg/m, 1,943 cm4). Use the maker's data for design. | Not yet rechecked by a second method; see the source. |
| Round Steel Tube (CHS) Section Properties | Circular hollow sections of the standard pipe outside diameters (EN 10210, EN 10219; see ISO 4200). Everything is exact geometry: A = pi/4 (D2 – d2), I = pi/64 (D4 – d4), W = I / (D/2), Wt = 2W, mass at 7,850 kg/m3. | Area, second moment, section modulus and mass recomputed from D and t (steel 7,850 kg/m³). |
| Square Hollow Section (SHS) Properties | Square hollow sections of common sizes (EN 10219, EN 10210). Corner radii follow EN 10219 (2t up to 6 mm wall, 2.5t up to 10 mm, 3t above); area, mass (7,850 kg/m3), I, W and i are computed from the dimensions including the corner radii. They agree with the makers' tables to within rounding (for example 100 x 100 x 5: 18.4 cm2, 14.4 kg/m). | Area recomputed from the outside size, wall and corner radius (EN 10219 rounded corners) and mass at 7,850 kg/m³. |
| Steel Bar Weight per Meter | Computed from the cross-section area and a density of 7,850 kg/m3 for steel and 2,700 kg/m3 for aluminum (round bar: pi/4 d2; square: d2; hexagon: (sqrt(3)/2) s2 with s across flats). 1 kg/m = 0.671969 lb/ft. Rolled bar is within about 2 to 3 percent of these figures. | Mass per meter recomputed from the cross-section (round, square, hexagon) at 7,850 kg/m³ for steel and 2,700 kg/m³ for aluminum; lb/ft at 0.671969 per kg/m. |
| Rebar Sizes (ASTM and Metric) | ASTM A615 / A615M reinforcing bar sizes (US numbers are eighths of an inch: #8 is 8/8 = 1 inch; #9, #10, #11, #14 and #18 have the diameter of the old square bars of equal area) and common metric sizes. Area and mass are computed from the nominal diameter at 7,850 kg/m3. | Area recomputed from the nominal diameter and mass at 7,850 kg/m³. |
| Wide-Flange (W) Beams Table: Dimensions and Section Properties | Machinery's Handbook, 31st edition (Industrial Press), Rolled Steel Sections, from the AISC Manual of Steel Construction, 8th edition (1980). Values were transcribed by script and verified against the geometry of each shape (S = I/c, r = sqrt(I/A), area = weight/3.403 lb per in2 of steel). Current AISC Manual shape lists and some properties differ slightly: use the current AISC Shapes Database for design. | Weight checked against the area (3.40 lb/ft per in² of steel at 490 lb/ft³) and kg/m against lb/ft (1.48816). |
| S Beams (American Standard I-Beams) Table | Machinery's Handbook, 31st edition (Industrial Press), Rolled Steel Sections, from the AISC Manual of Steel Construction, 8th edition (1980). Values were transcribed by script and verified against the geometry of each shape (S = I/c, r = sqrt(I/A), area = weight/3.403 lb per in2 of steel). Current AISC Manual shape lists and some properties differ slightly: use the current AISC Shapes Database for design. | Weight checked against the area (3.40 lb/ft per in² of steel at 490 lb/ft³) and kg/m against lb/ft (1.48816). |
| American Standard Steel Channels (C Shapes) Table | Machinery's Handbook, 31st edition (Industrial Press), Rolled Steel Sections, from the AISC Manual of Steel Construction, 8th edition (1980). Values were transcribed by script and verified against the geometry of each shape (S = I/c, r = sqrt(I/A), area = weight/3.403 lb per in2 of steel). Current AISC Manual shape lists and some properties differ slightly: use the current AISC Shapes Database for design. | Weight checked against the area (3.40 lb/ft per in² of steel at 490 lb/ft³) and kg/m against lb/ft (1.48816). |
| Steel Angles with Equal Legs Table (L Shapes) | Machinery's Handbook, 31st edition (Industrial Press), Rolled Steel Sections, from the AISC Manual of Steel Construction, 8th edition (1980). Values were transcribed by script and verified against the geometry of each shape (S = I/c, r = sqrt(I/A), area = weight/3.403 lb per in2 of steel). Current AISC Manual shape lists and some properties differ slightly: use the current AISC Shapes Database for design. | Area recomputed from the legs and thickness, t (a + b − t), and weight at 3.40 lb/ft per in²; kg/m from lb/ft. |
| Steel Angles with Unequal Legs Table (L Shapes) | Machinery's Handbook, 31st edition (Industrial Press), Rolled Steel Sections, from the AISC Manual of Steel Construction, 8th edition (1980). Values were transcribed by script and verified against the geometry of each shape (S = I/c, r = sqrt(I/A), area = weight/3.403 lb per in2 of steel). Current AISC Manual shape lists and some properties differ slightly: use the current AISC Shapes Database for design. | Area recomputed from the legs and thickness, t (a + b − t), and weight at 3.40 lb/ft per in²; kg/m from lb/ft. |