Superheated Steam Table (Specific Volume, Enthalpy, Entropy)

Superheated steam properties at 12 pressures from 10 kPa to 15 MPa and temperatures up to 600 °C: specific volume, internal energy, enthalpy and entropy.

Superheated steam is steam hotter than the boiling point for its pressure. It behaves more like a gas than wet steam, carries heat without condensing and is what turbines and many process heaters use. Its properties depend on both pressure and temperature, so the table is organized by pressure with rows for rising temperature.

For each of 12 pressures from 10 kPa to 15 MPa the table starts with the saturated vapor (the boiling-point steam) and then lists temperatures from 100 °C to 600 °C in 50 °C steps, wherever the steam is superheated. Columns give the specific volume (v), internal energy (u), enthalpy (h) and entropy (s). The values are computed from the IAPWS Industrial Formulation 1997 (IAPWS-IF97).

The table

114 rows
Pressure (kPa)StateTemperature (°C)v (m³/kg)u (kJ/kg)h (kJ/kg)s (kJ/kg·K)
10Saturated vapor45.8114.6712437.22583.98.1489
10Superheated100.0017.1972515.52687.48.4488
10Superheated150.0019.5142587.92783.08.6892
10Superheated200.0021.8262661.32879.68.9048
10Superheated250.0024.1362736.12977.49.1014
10Superheated300.0026.4462812.33076.79.2827
10Superheated350.0028.7552890.03177.59.4513
10Superheated400.0031.0642969.33279.99.6093
10Superheated450.0033.3723050.23384.09.7584
10Superheated500.0035.6803132.93489.79.8997
10Superheated550.0037.9883217.23597.110.0343
10Superheated600.0040.2963303.33706.310.1631
50Saturated vapor81.323.24012483.22645.27.5930
50Superheated100.003.41882511.52682.47.6952
50Superheated150.003.88992585.72780.27.9412
50Superheated200.004.35632660.02877.88.1591
50Superheated250.004.82072735.12976.28.3568
50Superheated300.005.28412811.63075.88.5386
50Superheated350.005.74702889.43176.88.7076
50Superheated400.006.20952968.83279.38.8658
50Superheated450.006.67183049.93383.59.0150
50Superheated500.007.13393132.63489.29.1565
50Superheated550.007.59593216.93596.79.2912
50Superheated600.008.05783303.13706.09.4200
100Saturated vapor99.611.69402505.52674.97.3588
100Superheated100.001.69602506.22675.87.3610
100Superheated150.001.93672582.92776.67.6147
100Superheated200.002.17252658.22875.57.8356
100Superheated250.002.40622733.92974.58.0346
100Superheated300.002.63892810.73074.58.2171
100Superheated350.002.87102888.73175.88.3865
100Superheated400.003.10272968.33278.58.5451
100Superheated450.003.33423049.43382.88.6945
100Superheated500.003.56563132.23488.78.8361
100Superheated550.003.79683216.63596.38.9709
100Superheated600.004.02793302.83705.69.0998
200Saturated vapor120.210.885742529.12706.27.1269
200Superheated150.000.959892577.12769.17.2809
200Superheated200.001.08052654.72870.87.5081
200Superheated250.001.19892731.52971.37.7100
200Superheated300.001.31622808.83072.17.8940
200Superheated350.001.43302887.33173.98.0643
200Superheated400.001.54932967.13277.08.2235
200Superheated450.001.66553048.43381.58.3733
200Superheated500.001.78143131.33487.68.5151
200Superheated550.001.89733215.93595.48.6501
200Superheated600.002.01303302.23704.88.7792
500Saturated vapor151.840.374802560.72748.16.8206
500Superheated200.000.425032643.42855.97.0611
500Superheated250.000.474432723.92961.17.2726
500Superheated300.000.522602803.33064.67.4614
500Superheated350.000.570142883.03168.17.6345
500Superheated400.000.617292963.63272.37.7954
500Superheated450.000.664213045.63377.77.9464
500Superheated500.000.710953128.93484.48.0891
500Superheated550.000.757573213.93592.68.2247
500Superheated600.000.804103300.43702.58.3543
1000Saturated vapor179.890.194352582.82777.16.5850
1000Superheated200.000.206002622.32828.36.6955
1000Superheated250.000.232742710.52943.26.9266
1000Superheated300.000.257982793.73051.77.1247
1000Superheated350.000.282492875.73158.27.3028
1000Superheated400.000.306592957.83264.47.4668
1000Superheated450.000.330443040.83371.27.6198
1000Superheated500.000.354113124.93479.07.7640
1000Superheated550.000.377663210.43588.17.9007
1000Superheated600.000.401113297.43698.68.0309
2000Saturated vapor212.380.0995812599.22798.46.3392
2000Superheated250.000.111482680.32903.26.5474
2000Superheated300.000.125502773.23024.36.7685
2000Superheated350.000.138592860.53137.66.9582
2000Superheated400.000.151212945.83248.27.1290
2000Superheated450.000.163543031.03358.17.2863
2000Superheated500.000.175683116.73468.17.4335
2000Superheated550.000.187693203.53578.97.5723
2000Superheated600.000.199613291.53690.77.7042
4000Saturated vapor250.360.0497772601.82800.96.0697
4000Superheated300.000.0588682726.22961.76.3638
4000Superheated350.000.0664742827.43093.36.5843
4000Superheated400.000.0734322920.63214.46.7712
4000Superheated450.000.0800423010.83331.06.9383
4000Superheated500.000.0864413100.13445.87.0919
4000Superheated550.000.0926993189.43560.27.2353
4000Superheated600.000.0988573279.43674.87.3704
6000Saturated vapor275.590.0324492589.92784.65.8901
6000Superheated300.000.0361912668.32885.56.0702
6000Superheated350.000.0422532790.33043.96.3356
6000Superheated400.000.0474232893.63178.26.5431
6000Superheated450.000.0521682989.83302.86.7216
6000Superheated500.000.0566723082.93422.96.8824
6000Superheated550.000.0610213175.13541.27.0306
6000Superheated600.000.0652643267.23658.87.1692
8000Saturated vapor295.010.0235282570.42758.65.7448
8000Superheated300.000.0242802592.12786.45.7935
8000Superheated350.000.0299782748.22988.16.1319
8000Superheated400.000.0343482864.53139.36.3657
8000Superheated450.000.0381972967.73273.26.5577
8000Superheated500.000.0417693065.23399.46.7264
8000Superheated550.000.0451723160.43521.86.8798
8000Superheated600.000.0484633254.73642.47.0221
10000Saturated vapor311.000.0180342545.12725.55.6159
10000Superheated350.000.0224422699.52924.05.9458
10000Superheated400.000.0264392833.03097.46.2139
10000Superheated450.000.0297852944.43242.36.4217
10000Superheated500.000.0328133046.93375.16.5993
10000Superheated550.000.0356553145.43501.96.7584
10000Superheated600.000.0383773242.13625.86.9045
15000Saturated vapor342.160.0103402455.82610.95.3108
15000Superheated350.000.0114812520.82693.05.4435
15000Superheated400.000.0156712740.52975.55.8817
15000Superheated450.000.0184782880.73157.86.1433
15000Superheated500.000.0208282998.43310.86.3479
15000Superheated550.000.0229453106.33450.56.5230
15000Superheated600.000.0249213209.53583.36.6797

Source and notes: Computed by Engineer Underground from the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam (IAPWS-IF97, revised release R7-97(2012)), regions 1, 2 and 4. The implementation reproduces the release's own verification values to 8 digits. Reference state: internal energy and entropy are zero for saturated liquid at the triple point (0.01 C). Each row was also checked for h = u + P v and against the Clausius-Clapeyron relation. Values can differ in the fourth or fifth digit from tables built on the IAPWS-95 formulation.

How to use this table

  1. Find the pressure (absolute) in the first column, then the row for your temperature. If your temperature is not in the table, interpolate between the two rows either side of it.
  2. If your temperature is at or below the first row for that pressure (the saturated vapor), the steam is not superheated: use the Saturated Steam Table.
  3. The heat needed to superheat steam at constant pressure is the difference in enthalpy between two rows: q = h2 − h1. The work from an ideal (isentropic) turbine expansion is found by keeping s constant.

Worked example: superheating 10 bar steam, and how density changes

  • Heating dry saturated steam at 1 MPa (179.89 °C, h = 2777.1 kJ/kg) to 400 °C (h = 3264.4 kJ/kg) takes q = 3264.4 − 2777.1 = 487.3 kJ/kg. At 1 kg/s that is 487 kW. The specific volume rises from 0.19435 to 0.30659 m³/kg, so the steam expands by 58 percent.
  • The same 400 °C steam at 1 MPa and at 4 MPa: at the higher pressure the enthalpy is a little lower (h = 3214.4 kJ/kg against 3264.4 kJ/kg) and the steam is much denser, taking up 76 percent less space (0.073432 against 0.30659 m³/kg). The entropy values (6.7712 and 7.4668 kJ/kg·K) are what an isentropic turbine calculation uses.

Notes and cautions

  • Rows are shown only where the steam is superheated. For example at 1 MPa the first superheated row is 200 °C because saturation is at 179.89 °C; at 15 MPa it is 350 °C because saturation is at 342.16 °C.
  • The pressure is absolute. The table stops at 15 MPa, where the IAPWS-IF97 steam equation applies across the whole temperature range shown.
  • The first row of each pressure is the saturated vapor, shown with its own temperature, so you can see where superheat starts.
  • For an isentropic turbine expansion between two pressures, look for the same entropy at the exit: this usually means a wet mixture, so use the Saturated Steam Table to find the dryness fraction.
  • IAPWS-IF97 agrees with the scientific IAPWS-95 formulation to within a few hundredths of a percent in this range, so a textbook table can differ from this one in the fourth or fifth digit.

FAQ

What is superheated steam?

Steam at a temperature above the saturation (boiling) temperature for its pressure. It has no liquid in it, so cooling it first lowers its temperature until it reaches saturation, and only then does it start to condense.

What is the enthalpy of steam at 10 bar and 300 °C?

3,051.7 kJ/kg (the 1,000 kPa and 300 °C row). The saturated vapor at that pressure has 2,777.1 kJ/kg.

How much heat does it take to superheat steam?

The enthalpy difference between the two states at the same pressure, for instance 487.3 kJ/kg to take 10 bar steam from saturation (2,777.1) to 400 °C (3,264.4).

Why use superheated steam in turbines?

It lets the steam expand through the turbine without condensing too early, which would erode the blades, and it raises the cycle efficiency.

Where is wet steam in these tables?

Wet steam (a mixture of liquid and vapor) lies between the saturated liquid and saturated vapor and is found with the dryness fraction from the Saturated Steam Table.

Sources

  • IAPWS, Revised Release on the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam, R7-97(2012). Publication in whole or in part is allowed with attribution to the International Association for the Properties of Water and Steam.
  • Wagner, W. et al., “The IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam”, J. Eng. Gas Turbines Power 122 (2000) 150-182.
  • Cengel, Y. A. and Boles, M. A., Thermodynamics: An Engineering Approach, McGraw-Hill: steam tables (for comparison; tables built on the IAPWS-95 formulation can differ in the fourth or fifth digit).
  • Computed by Engineer Underground from the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam (IAPWS-IF97, revised release R7-97(2012)), regions 1, 2 and 4. The implementation reproduces the release's own verification values to 8 digits. Reference state: internal energy and entropy are zero for saturated liquid at the triple point (0.01 C). Each row was also checked for h = u + P v and against the Clausius-Clapeyron relation. Values can differ in the fourth or fifth digit from tables built on the IAPWS-95 formulation.

Published by Nick Peterson, mechanical engineer.