Superheated Steam Table (Specific Volume, Enthalpy, Entropy)
Superheated steam properties at 12 pressures from 10 kPa to 15 MPa and temperatures up to 600 °C: specific volume, internal energy, enthalpy and entropy.
Superheated steam is steam hotter than the boiling point for its pressure. It behaves more like a gas than wet steam, carries heat without condensing and is what turbines and many process heaters use. Its properties depend on both pressure and temperature, so the table is organized by pressure with rows for rising temperature.
For each of 12 pressures from 10 kPa to 15 MPa the table starts with the saturated vapor (the boiling-point steam) and then lists temperatures from 100 °C to 600 °C in 50 °C steps, wherever the steam is superheated. Columns give the specific volume (v), internal energy (u), enthalpy (h) and entropy (s). The values are computed from the IAPWS Industrial Formulation 1997 (IAPWS-IF97).
The table
| Pressure (kPa) | State | Temperature (°C) | v (m³/kg) | u (kJ/kg) | h (kJ/kg) | s (kJ/kg·K) |
|---|---|---|---|---|---|---|
| 10 | Saturated vapor | 45.81 | 14.671 | 2437.2 | 2583.9 | 8.1489 |
| 10 | Superheated | 100.00 | 17.197 | 2515.5 | 2687.4 | 8.4488 |
| 10 | Superheated | 150.00 | 19.514 | 2587.9 | 2783.0 | 8.6892 |
| 10 | Superheated | 200.00 | 21.826 | 2661.3 | 2879.6 | 8.9048 |
| 10 | Superheated | 250.00 | 24.136 | 2736.1 | 2977.4 | 9.1014 |
| 10 | Superheated | 300.00 | 26.446 | 2812.3 | 3076.7 | 9.2827 |
| 10 | Superheated | 350.00 | 28.755 | 2890.0 | 3177.5 | 9.4513 |
| 10 | Superheated | 400.00 | 31.064 | 2969.3 | 3279.9 | 9.6093 |
| 10 | Superheated | 450.00 | 33.372 | 3050.2 | 3384.0 | 9.7584 |
| 10 | Superheated | 500.00 | 35.680 | 3132.9 | 3489.7 | 9.8997 |
| 10 | Superheated | 550.00 | 37.988 | 3217.2 | 3597.1 | 10.0343 |
| 10 | Superheated | 600.00 | 40.296 | 3303.3 | 3706.3 | 10.1631 |
| 50 | Saturated vapor | 81.32 | 3.2401 | 2483.2 | 2645.2 | 7.5930 |
| 50 | Superheated | 100.00 | 3.4188 | 2511.5 | 2682.4 | 7.6952 |
| 50 | Superheated | 150.00 | 3.8899 | 2585.7 | 2780.2 | 7.9412 |
| 50 | Superheated | 200.00 | 4.3563 | 2660.0 | 2877.8 | 8.1591 |
| 50 | Superheated | 250.00 | 4.8207 | 2735.1 | 2976.2 | 8.3568 |
| 50 | Superheated | 300.00 | 5.2841 | 2811.6 | 3075.8 | 8.5386 |
| 50 | Superheated | 350.00 | 5.7470 | 2889.4 | 3176.8 | 8.7076 |
| 50 | Superheated | 400.00 | 6.2095 | 2968.8 | 3279.3 | 8.8658 |
| 50 | Superheated | 450.00 | 6.6718 | 3049.9 | 3383.5 | 9.0150 |
| 50 | Superheated | 500.00 | 7.1339 | 3132.6 | 3489.2 | 9.1565 |
| 50 | Superheated | 550.00 | 7.5959 | 3216.9 | 3596.7 | 9.2912 |
| 50 | Superheated | 600.00 | 8.0578 | 3303.1 | 3706.0 | 9.4200 |
| 100 | Saturated vapor | 99.61 | 1.6940 | 2505.5 | 2674.9 | 7.3588 |
| 100 | Superheated | 100.00 | 1.6960 | 2506.2 | 2675.8 | 7.3610 |
| 100 | Superheated | 150.00 | 1.9367 | 2582.9 | 2776.6 | 7.6147 |
| 100 | Superheated | 200.00 | 2.1725 | 2658.2 | 2875.5 | 7.8356 |
| 100 | Superheated | 250.00 | 2.4062 | 2733.9 | 2974.5 | 8.0346 |
| 100 | Superheated | 300.00 | 2.6389 | 2810.7 | 3074.5 | 8.2171 |
| 100 | Superheated | 350.00 | 2.8710 | 2888.7 | 3175.8 | 8.3865 |
| 100 | Superheated | 400.00 | 3.1027 | 2968.3 | 3278.5 | 8.5451 |
| 100 | Superheated | 450.00 | 3.3342 | 3049.4 | 3382.8 | 8.6945 |
| 100 | Superheated | 500.00 | 3.5656 | 3132.2 | 3488.7 | 8.8361 |
| 100 | Superheated | 550.00 | 3.7968 | 3216.6 | 3596.3 | 8.9709 |
| 100 | Superheated | 600.00 | 4.0279 | 3302.8 | 3705.6 | 9.0998 |
| 200 | Saturated vapor | 120.21 | 0.88574 | 2529.1 | 2706.2 | 7.1269 |
| 200 | Superheated | 150.00 | 0.95989 | 2577.1 | 2769.1 | 7.2809 |
| 200 | Superheated | 200.00 | 1.0805 | 2654.7 | 2870.8 | 7.5081 |
| 200 | Superheated | 250.00 | 1.1989 | 2731.5 | 2971.3 | 7.7100 |
| 200 | Superheated | 300.00 | 1.3162 | 2808.8 | 3072.1 | 7.8940 |
| 200 | Superheated | 350.00 | 1.4330 | 2887.3 | 3173.9 | 8.0643 |
| 200 | Superheated | 400.00 | 1.5493 | 2967.1 | 3277.0 | 8.2235 |
| 200 | Superheated | 450.00 | 1.6655 | 3048.4 | 3381.5 | 8.3733 |
| 200 | Superheated | 500.00 | 1.7814 | 3131.3 | 3487.6 | 8.5151 |
| 200 | Superheated | 550.00 | 1.8973 | 3215.9 | 3595.4 | 8.6501 |
| 200 | Superheated | 600.00 | 2.0130 | 3302.2 | 3704.8 | 8.7792 |
| 500 | Saturated vapor | 151.84 | 0.37480 | 2560.7 | 2748.1 | 6.8206 |
| 500 | Superheated | 200.00 | 0.42503 | 2643.4 | 2855.9 | 7.0611 |
| 500 | Superheated | 250.00 | 0.47443 | 2723.9 | 2961.1 | 7.2726 |
| 500 | Superheated | 300.00 | 0.52260 | 2803.3 | 3064.6 | 7.4614 |
| 500 | Superheated | 350.00 | 0.57014 | 2883.0 | 3168.1 | 7.6345 |
| 500 | Superheated | 400.00 | 0.61729 | 2963.6 | 3272.3 | 7.7954 |
| 500 | Superheated | 450.00 | 0.66421 | 3045.6 | 3377.7 | 7.9464 |
| 500 | Superheated | 500.00 | 0.71095 | 3128.9 | 3484.4 | 8.0891 |
| 500 | Superheated | 550.00 | 0.75757 | 3213.9 | 3592.6 | 8.2247 |
| 500 | Superheated | 600.00 | 0.80410 | 3300.4 | 3702.5 | 8.3543 |
| 1000 | Saturated vapor | 179.89 | 0.19435 | 2582.8 | 2777.1 | 6.5850 |
| 1000 | Superheated | 200.00 | 0.20600 | 2622.3 | 2828.3 | 6.6955 |
| 1000 | Superheated | 250.00 | 0.23274 | 2710.5 | 2943.2 | 6.9266 |
| 1000 | Superheated | 300.00 | 0.25798 | 2793.7 | 3051.7 | 7.1247 |
| 1000 | Superheated | 350.00 | 0.28249 | 2875.7 | 3158.2 | 7.3028 |
| 1000 | Superheated | 400.00 | 0.30659 | 2957.8 | 3264.4 | 7.4668 |
| 1000 | Superheated | 450.00 | 0.33044 | 3040.8 | 3371.2 | 7.6198 |
| 1000 | Superheated | 500.00 | 0.35411 | 3124.9 | 3479.0 | 7.7640 |
| 1000 | Superheated | 550.00 | 0.37766 | 3210.4 | 3588.1 | 7.9007 |
| 1000 | Superheated | 600.00 | 0.40111 | 3297.4 | 3698.6 | 8.0309 |
| 2000 | Saturated vapor | 212.38 | 0.099581 | 2599.2 | 2798.4 | 6.3392 |
| 2000 | Superheated | 250.00 | 0.11148 | 2680.3 | 2903.2 | 6.5474 |
| 2000 | Superheated | 300.00 | 0.12550 | 2773.2 | 3024.3 | 6.7685 |
| 2000 | Superheated | 350.00 | 0.13859 | 2860.5 | 3137.6 | 6.9582 |
| 2000 | Superheated | 400.00 | 0.15121 | 2945.8 | 3248.2 | 7.1290 |
| 2000 | Superheated | 450.00 | 0.16354 | 3031.0 | 3358.1 | 7.2863 |
| 2000 | Superheated | 500.00 | 0.17568 | 3116.7 | 3468.1 | 7.4335 |
| 2000 | Superheated | 550.00 | 0.18769 | 3203.5 | 3578.9 | 7.5723 |
| 2000 | Superheated | 600.00 | 0.19961 | 3291.5 | 3690.7 | 7.7042 |
| 4000 | Saturated vapor | 250.36 | 0.049777 | 2601.8 | 2800.9 | 6.0697 |
| 4000 | Superheated | 300.00 | 0.058868 | 2726.2 | 2961.7 | 6.3638 |
| 4000 | Superheated | 350.00 | 0.066474 | 2827.4 | 3093.3 | 6.5843 |
| 4000 | Superheated | 400.00 | 0.073432 | 2920.6 | 3214.4 | 6.7712 |
| 4000 | Superheated | 450.00 | 0.080042 | 3010.8 | 3331.0 | 6.9383 |
| 4000 | Superheated | 500.00 | 0.086441 | 3100.1 | 3445.8 | 7.0919 |
| 4000 | Superheated | 550.00 | 0.092699 | 3189.4 | 3560.2 | 7.2353 |
| 4000 | Superheated | 600.00 | 0.098857 | 3279.4 | 3674.8 | 7.3704 |
| 6000 | Saturated vapor | 275.59 | 0.032449 | 2589.9 | 2784.6 | 5.8901 |
| 6000 | Superheated | 300.00 | 0.036191 | 2668.3 | 2885.5 | 6.0702 |
| 6000 | Superheated | 350.00 | 0.042253 | 2790.3 | 3043.9 | 6.3356 |
| 6000 | Superheated | 400.00 | 0.047423 | 2893.6 | 3178.2 | 6.5431 |
| 6000 | Superheated | 450.00 | 0.052168 | 2989.8 | 3302.8 | 6.7216 |
| 6000 | Superheated | 500.00 | 0.056672 | 3082.9 | 3422.9 | 6.8824 |
| 6000 | Superheated | 550.00 | 0.061021 | 3175.1 | 3541.2 | 7.0306 |
| 6000 | Superheated | 600.00 | 0.065264 | 3267.2 | 3658.8 | 7.1692 |
| 8000 | Saturated vapor | 295.01 | 0.023528 | 2570.4 | 2758.6 | 5.7448 |
| 8000 | Superheated | 300.00 | 0.024280 | 2592.1 | 2786.4 | 5.7935 |
| 8000 | Superheated | 350.00 | 0.029978 | 2748.2 | 2988.1 | 6.1319 |
| 8000 | Superheated | 400.00 | 0.034348 | 2864.5 | 3139.3 | 6.3657 |
| 8000 | Superheated | 450.00 | 0.038197 | 2967.7 | 3273.2 | 6.5577 |
| 8000 | Superheated | 500.00 | 0.041769 | 3065.2 | 3399.4 | 6.7264 |
| 8000 | Superheated | 550.00 | 0.045172 | 3160.4 | 3521.8 | 6.8798 |
| 8000 | Superheated | 600.00 | 0.048463 | 3254.7 | 3642.4 | 7.0221 |
| 10000 | Saturated vapor | 311.00 | 0.018034 | 2545.1 | 2725.5 | 5.6159 |
| 10000 | Superheated | 350.00 | 0.022442 | 2699.5 | 2924.0 | 5.9458 |
| 10000 | Superheated | 400.00 | 0.026439 | 2833.0 | 3097.4 | 6.2139 |
| 10000 | Superheated | 450.00 | 0.029785 | 2944.4 | 3242.3 | 6.4217 |
| 10000 | Superheated | 500.00 | 0.032813 | 3046.9 | 3375.1 | 6.5993 |
| 10000 | Superheated | 550.00 | 0.035655 | 3145.4 | 3501.9 | 6.7584 |
| 10000 | Superheated | 600.00 | 0.038377 | 3242.1 | 3625.8 | 6.9045 |
| 15000 | Saturated vapor | 342.16 | 0.010340 | 2455.8 | 2610.9 | 5.3108 |
| 15000 | Superheated | 350.00 | 0.011481 | 2520.8 | 2693.0 | 5.4435 |
| 15000 | Superheated | 400.00 | 0.015671 | 2740.5 | 2975.5 | 5.8817 |
| 15000 | Superheated | 450.00 | 0.018478 | 2880.7 | 3157.8 | 6.1433 |
| 15000 | Superheated | 500.00 | 0.020828 | 2998.4 | 3310.8 | 6.3479 |
| 15000 | Superheated | 550.00 | 0.022945 | 3106.3 | 3450.5 | 6.5230 |
| 15000 | Superheated | 600.00 | 0.024921 | 3209.5 | 3583.3 | 6.6797 |
Source and notes: Computed by Engineer Underground from the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam (IAPWS-IF97, revised release R7-97(2012)), regions 1, 2 and 4. The implementation reproduces the release's own verification values to 8 digits. Reference state: internal energy and entropy are zero for saturated liquid at the triple point (0.01 C). Each row was also checked for h = u + P v and against the Clausius-Clapeyron relation. Values can differ in the fourth or fifth digit from tables built on the IAPWS-95 formulation.
How to use this table
- Find the pressure (absolute) in the first column, then the row for your temperature. If your temperature is not in the table, interpolate between the two rows either side of it.
- If your temperature is at or below the first row for that pressure (the saturated vapor), the steam is not superheated: use the Saturated Steam Table.
- The heat needed to superheat steam at constant pressure is the difference in enthalpy between two rows: q = h2 − h1. The work from an ideal (isentropic) turbine expansion is found by keeping s constant.
Worked example: superheating 10 bar steam, and how density changes
- Heating dry saturated steam at 1 MPa (179.89 °C, h = 2777.1 kJ/kg) to 400 °C (h = 3264.4 kJ/kg) takes q = 3264.4 − 2777.1 = 487.3 kJ/kg. At 1 kg/s that is 487 kW. The specific volume rises from 0.19435 to 0.30659 m³/kg, so the steam expands by 58 percent.
- The same 400 °C steam at 1 MPa and at 4 MPa: at the higher pressure the enthalpy is a little lower (h = 3214.4 kJ/kg against 3264.4 kJ/kg) and the steam is much denser, taking up 76 percent less space (0.073432 against 0.30659 m³/kg). The entropy values (6.7712 and 7.4668 kJ/kg·K) are what an isentropic turbine calculation uses.
Notes and cautions
- Rows are shown only where the steam is superheated. For example at 1 MPa the first superheated row is 200 °C because saturation is at 179.89 °C; at 15 MPa it is 350 °C because saturation is at 342.16 °C.
- The pressure is absolute. The table stops at 15 MPa, where the IAPWS-IF97 steam equation applies across the whole temperature range shown.
- The first row of each pressure is the saturated vapor, shown with its own temperature, so you can see where superheat starts.
- For an isentropic turbine expansion between two pressures, look for the same entropy at the exit: this usually means a wet mixture, so use the Saturated Steam Table to find the dryness fraction.
- IAPWS-IF97 agrees with the scientific IAPWS-95 formulation to within a few hundredths of a percent in this range, so a textbook table can differ from this one in the fourth or fifth digit.
Related tools and guides
- Saturated Steam Table by Temperature
- Saturated Steam Table by Pressure
- Steam Power Cycles (Rankine)
- Thermodynamics and Steam guide
- All reference tables
FAQ
What is superheated steam?
Steam at a temperature above the saturation (boiling) temperature for its pressure. It has no liquid in it, so cooling it first lowers its temperature until it reaches saturation, and only then does it start to condense.
What is the enthalpy of steam at 10 bar and 300 °C?
3,051.7 kJ/kg (the 1,000 kPa and 300 °C row). The saturated vapor at that pressure has 2,777.1 kJ/kg.
How much heat does it take to superheat steam?
The enthalpy difference between the two states at the same pressure, for instance 487.3 kJ/kg to take 10 bar steam from saturation (2,777.1) to 400 °C (3,264.4).
Why use superheated steam in turbines?
It lets the steam expand through the turbine without condensing too early, which would erode the blades, and it raises the cycle efficiency.
Where is wet steam in these tables?
Wet steam (a mixture of liquid and vapor) lies between the saturated liquid and saturated vapor and is found with the dryness fraction from the Saturated Steam Table.
Sources
- IAPWS, Revised Release on the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam, R7-97(2012). Publication in whole or in part is allowed with attribution to the International Association for the Properties of Water and Steam.
- Wagner, W. et al., “The IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam”, J. Eng. Gas Turbines Power 122 (2000) 150-182.
- Cengel, Y. A. and Boles, M. A., Thermodynamics: An Engineering Approach, McGraw-Hill: steam tables (for comparison; tables built on the IAPWS-95 formulation can differ in the fourth or fifth digit).
- Computed by Engineer Underground from the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam (IAPWS-IF97, revised release R7-97(2012)), regions 1, 2 and 4. The implementation reproduces the release's own verification values to 8 digits. Reference state: internal energy and entropy are zero for saturated liquid at the triple point (0.01 C). Each row was also checked for h = u + P v and against the Clausius-Clapeyron relation. Values can differ in the fourth or fifth digit from tables built on the IAPWS-95 formulation.