UHMW polyethylene
Properties of UHMW polyethylene, each value tied to a recorded source.
A very tough polyethylene with a low-friction surface, wear and corrosion resistance, excellent impact strength and an FDA-compliant composition. It is used for chain guides, bearings and scrapers, but it is soft and has a low heat limit (about 80 °C long term in air).
Properties
| Property | SI | US customary | Basis | Source |
|---|---|---|---|---|
| Physical | ||||
| Density | 0.930 g/cm³ | 0.0336 lb/in³ | typical, ISO 1183-1 (specific gravity 0.93 by ASTM D792) | 1 |
| Water absorption | 0.100 % | typical, after 24 h immersion at 23 °C, ISO 62 | 1 | |
| Water absorption | 0.100 % | typical, at saturation in water at 23 °C | 1 | |
| Mechanical | ||||
| Elastic modulus (Young's) | 0.750 GPa | 0.109 Msi | typical, tensile, ISO 527-1/-2 (Printed as 750 MPa.) | 1 |
| Elastic modulus (Young's) | 0.550 GPa | 0.0798 Msi | typical, tensile, ASTM D638 (80 ksi) (Printed in ksi; converted at 1 ksi = 6.894757 MPa.) | 1 |
| Yield strength | 19 MPa | 2.76 ksi | typical, ISO 527-1/-2, tensile strength at yield (strain at yield 15 %; the sheet notes say tensile strength is at yield when strain at yield is reported) | 1 |
| Tensile strength (ultimate or at break) | 40 MPa | 5.80 ksi | typical, ASTM D638 (5,800 psi; basis, yield or break, not stated) (Printed in psi; converted at 1 psi = 0.006894757 MPa.) | 1 |
| Elongation at break | 50 % | minimum, at break, ISO 527-1/-2 (printed as > 50) | 1 | |
| Elongation at break | 300 % | typical, at break, ASTM D638 | 1 | |
| Shear strength | 33 MPa | 4.79 ksi | typical, ASTM D732 (printed as 33 MPa and 4,800 psi) | 1 |
| Flexural strength | 17 MPa | 2.47 ksi | typical, ISO 178 | 1 |
| Flexural strength | 24 MPa | 3.50 ksi | typical, ASTM D790 (3,500 psi) (Printed in psi; converted at 1 psi = 0.006894757 MPa.) | 1 |
| Flexural modulus | 0.600 GPa | 0.0870 Msi | typical, ASTM D790 (87 ksi; no ISO value printed) (Printed in ksi; converted at 1 ksi = 6.894757 MPa.) | 1 |
| Thermal | ||||
| Melting point (as published) | 135 °C | 275 °F | typical, DSC, 10 °C/min, ISO 11357-1/-3 (ASTM D3418 column: 275 °F) | 1 |
| Thermal conductivity | 0.400 W/m·K | 2.77 BTU·in/h·ft²·°F | typical, at 23 °C | 1 |
| Thermal expansion (linear) | 200.0 µm/m·K | 111 µin/in·°F | typical, 23 to 100 °C | 1 |
| Thermal expansion (linear) | 198.0 µm/m·K | 110 µin/in·°F | typical, -40 to 150 °C, ASTM E-831 (110 µin/in/°F) (Printed as 110 µin./in./°F; converted at 1 µin/in·°F = 1.8 µm/m·K.) | 1 |
| Heat deflection temperature | 42 °C | 108 °F | typical, at 1.8 MPa, method A, ISO 75-1/-2 | 1 |
| Heat deflection temperature | 47 °C | 116 °F | typical, at 1.8 MPa (264 psi), ASTM D648 (116 °F) (Printed as 116 °F; converted to °C.) | 1 |
| Maximum service temperature | 80 °C | 176 °F | typical, continuous allowable service temperature in air (20,000 h) | 1 |
Things to know
- The sheet's footnote 1 says most of its thermal figures come from raw material supplier data and other publications, not the maker's own tests. Its notes call all values indicative and say they should not be used as specification limits.
- ISO and ASTM values differ because the test methods differ (for example 19 MPa at yield by ISO and 5,800 psi by ASTM). The notched Charpy value prints as "115P" with the suffix not defined, so it is left out; unnotched Charpy is printed as no break.
- Other values on the sheet: minimum service temperature -200 °C, UL 94 HB (3 mm, estimated), oxygen index 20 percent, Shore D 60 (ISO) and 66 (ASTM), dynamic coefficient of friction 0.15 to 0.30 (ISO 7148-2) and 0.12 (QTM 55007).
Sources
- Mitsubishi Chemical Advanced Materials: TIVAR 1000 Virgin UHMW-PE Product Datasheet (ISO and ASTM indicative values; date of issue 28/09/2026) mcam.com/mam/54452/PE-TIVAR%E2%84%A2%201000%20Virgin%20UHMW-PE_en_US.pdf (the maker of the material; read 2026-11-17)
Typical values are not guaranteed and must not be used as design minimums. Minimum and maximum values apply to the forms, thicknesses and conditions stated. Where two sources differ, both are shown. Always confirm with the specification, the material certificate and your supplier before you rely on a number. The values were read from the cited sources on 2026-11-17.