O-Ring Groove Design Chart (Depth, Width and Squeeze)

Starting dimensions for O-ring grooves from the cross-section: groove depth and width for static and dynamic seals, with the squeeze.

An O-ring seals because it is squeezed between two surfaces. The groove it sits in controls how much: too deep and the ring is loose and leaks, too shallow and it is over-squeezed, wears and can be damaged on assembly. The depth is set by the cross-section of the ring (its thickness) and by whether the seal is static or moves.

The usual starting values are a squeeze of about 15 to 30 percent for a static seal and about 8 to 16 percent for a dynamic seal, in a groove about 1.3 to 1.5 times the cross-section wide, so the ring has room to deform without filling the groove. The table computes the groove dimensions for the common cross-sections at 20 percent static squeeze and 12 percent dynamic squeeze.

The table

14 rows
Cross-section (mm)Cross-section (in)Static seal: groove depth at 20 % squeeze (mm)Static seal: groove width (mm)Dynamic seal: groove depth at 12 % squeeze (mm)Dynamic seal: groove width (mm)Squeeze at 15 % (mm)Squeeze at 30 % (mm)
10.03940.81.350.881.40.150.3
1.50.05911.22.031.322.10.230.45
1.780.07011.422.41.572.490.270.53
20.07871.62.71.762.80.30.6
2.50.098423.382.23.50.380.75
2.620.10312.13.542.313.670.390.79
30.11812.44.052.644.20.450.9
3.530.1392.824.773.114.940.531.06
40.15753.25.43.525.60.61.2
50.196946.754.470.751.5
5.330.20984.267.24.697.460.81.6
60.23624.88.15.288.40.91.8
6.990.27525.599.446.159.791.052.1
80.3156.410.87.0411.21.22.4

Source and notes: Rules of thumb computed from the cross-section: static seals are squeezed about 15 to 30 percent (20 percent shown) in a groove about 1.3 to 1.5 times the cross-section wide; dynamic seals about 8 to 16 percent (12 percent shown) in a groove about 1.4 times wide. These are typical starting values: the O-ring maker’s gland tables (for example for AS568 and ISO 3601 sizes) and the pressure, fluid, temperature and material govern the final design. The last two columns give the amount of squeeze, in millimeters, at 15 and 30 percent of the cross-section.

How to use this table

  1. Find the cross-section of your O-ring (in millimeters or inches) in the first two columns.
  2. Read the groove depth and width for a static seal (a face or a bore with no motion) or a dynamic seal (a rod or piston that moves).
  3. Check the result against the O-ring maker’s gland tables, which also give tolerances, the effect of pressure and temperature, and back-up ring requirements.

Worked example: a 3.53 mm O-ring (AS568 -2xx series)

  • A ring of 3.53 mm cross-section (0.139 in) in a static face seal needs a groove depth of 3.53 × 0.80 = 2.82 mm, so it is squeezed by 3.53 − 2.82 = 0.71 mm (20 percent).
  • The groove width is about 1.35 × 3.53 = 4.77 mm.
  • For a dynamic rod seal the same ring sits in a groove 3.11 mm deep and 4.94 mm wide, squeezed by only 12 percent to keep friction and wear down.

Notes and cautions

  • These are typical starting dimensions computed from percentages, not a replacement for the maker’s gland tables. The right values depend on the material, the fluid, the temperature, the pressure and whether back-up rings are used.
  • The groove depth in a bore or rod gland is measured from the sealing surface; allow for the diametral clearance in the depth you use.
  • Dynamic seals need a smoother surface (about Ra 0.2 to 0.4 µm) than static seals (about Ra 1.6 µm) and benefit from lubrication.
  • Common cross-sections: AS568 inch series are 0.070, 0.103, 0.139, 0.210 and 0.275 in; ISO 3601 metric rings are 1.8, 2.65, 3.55, 5.3 and 7 mm. The table includes those and other sizes in between.

FAQ

How deep should an O-ring groove be?

About 80 percent of the cross-section for a static seal (20 percent squeeze) and about 88 percent for a dynamic seal (12 percent squeeze).

How wide should an O-ring groove be?

About 1.3 to 1.5 times the cross-section, so the ring has room to deform without filling the groove completely.

How much should an O-ring be squeezed?

15 to 30 percent for a static seal and 8 to 16 percent for a dynamic seal. More squeeze seals better but raises friction and wear and can damage the ring on assembly.

What is the difference between a static and a dynamic O-ring seal?

A static seal sits between parts that do not move relative to each other. A dynamic seal sits between parts that slide or rotate.

Sources

  • SAE AS568, Aerospace Size Standard for O-Rings.
  • ISO 3601, Fluid power systems: O-rings. O-ring makers’ design guides (for example Parker O-Ring Handbook) for the full gland tables.
  • Rules of thumb computed from the cross-section: static seals are squeezed about 15 to 30 percent (20 percent shown) in a groove about 1.3 to 1.5 times the cross-section wide; dynamic seals about 8 to 16 percent (12 percent shown) in a groove about 1.4 times wide. These are typical starting values: the O-ring maker’s gland tables (for example for AS568 and ISO 3601 sizes) and the pressure, fluid, temperature and material govern the final design. The last two columns give the amount of squeeze, in millimeters, at 15 and 30 percent of the cross-section.

Published by Nick Peterson, mechanical engineer.