Viscosity of Water vs Temperature (Dynamic and Kinematic)

Dynamic and kinematic viscosity of water from 0 to 100 °C in SI and US units, cP and cSt.

The viscosity of water at 20 °C is 1.002 mPa·s (1.002 centipoise, the dynamic viscosity) and 1.004 mm²/s (1.004 centistokes, the kinematic viscosity). It falls quickly as water warms: it is 1.79 mPa·s at 0 °C, 0.89 at 25 °C and 0.28 at 100 °C.

This table gives both viscosities every 5 °C in SI and US units. Dynamic viscosity (μ) is used for shear stress and pumping; kinematic viscosity (ν = μ ÷ ρ) goes into the Reynolds number.

The table

21 rows
Temperature (°C)Temperature (°F)Dynamic viscosity (mPa·s = cP)Dynamic viscosity (Pa·s)Dynamic viscosity (lb/ft·s)Kinematic viscosity (mm²/s = cSt)Kinematic viscosity (m²/s)Kinematic viscosity (ft²/s)
0321.7920.0017920.00120421.79231.7923E-61.9292E-5
5411.52320.00152320.00102361.52331.5233E-61.6396E-5
10501.3070.0013070.00087831.30741.3074E-61.4073E-5
15591.13820.00113820.00076491.13931.1393E-61.2263E-5
20681.0020.0010020.00067331.00381.0038E-61.0805E-5
25770.890.000890.0005980.89268.926E-79.608E-6
30860.7970.0007970.00053560.80058.005E-78.616E-6
35950.71910.00071910.00048320.72347.234E-77.787E-6
401040.6530.0006530.00043880.65816.581E-77.084E-6
451130.59610.00059610.00040060.6026.02E-76.48E-6
501220.5470.0005470.00036760.55365.536E-75.959E-6
551310.50440.00050440.00033890.51175.117E-75.508E-6
601400.4670.0004670.00031380.4754.75E-75.113E-6
651490.43360.00043360.00029130.44224.422E-74.76E-6
701580.4040.0004040.00027150.41324.132E-74.447E-6
751670.37810.00037810.00025410.38793.879E-74.175E-6
801760.3550.0003550.00023850.36533.653E-73.932E-6
851850.3340.0003340.00022440.34483.448E-73.712E-6
901940.3150.0003150.00021170.32633.263E-73.512E-6
952030.29780.00029780.00020010.30963.096E-73.332E-6
1002120.2820.0002820.00018950.29432.943E-73.167E-6

Source and notes: Handbook values every 10 °C (CRC Handbook, IAPWS) for liquid water at about 1 atm; values at 5 °C, 15 °C and so on are interpolated (about 0.3 percent, following the exponential trend). Kinematic viscosity = dynamic viscosity ÷ density (Kell). 1 Pa·s = 0.671969 lb/ft·s; 1 m²/s = 10.7639 ft²/s.

How to use this table

  1. Find the water temperature and take the dynamic or kinematic viscosity in the units you want (cP and cSt are the common ones).
  2. The Reynolds number of a flow is Re = V D ÷ ν, with ν in m²/s: use the kinematic column.
  3. Convert: 1 mPa·s = 1 cP = 0.001 Pa·s; 1 mm²/s = 1 cSt = 10⁻⁶ m²/s.

Worked example: Reynolds number in a 50 mm pipe at 1.5 m/s

  • At 20 °C the kinematic viscosity is 1.0038 mm²/s, so Re = 1.5 × 0.05 ÷ 1.0038×10⁻⁶ = 74,700 (turbulent).
  • At 60 °C the viscosity is 0.4750 mm²/s, 2.11 times lower, so Re is 157,900: the same flow is 2.1 times more turbulent.
  • Dynamic viscosity of 20 °C water: 1.002 mPa·s = 0.001002 Pa·s = 6.733×10⁻⁴ lb/(ft·s).

Notes and cautions

  • Viscosity depends strongly on temperature: it halves between 20 and 50 °C. Use the viscosity at the working temperature of the fluid.
  • Pressure has little effect on the viscosity of water at normal pressures (less than 1 percent per 100 bar).
  • Seawater is about 8 percent more viscous than fresh water at the same temperature, and brines and glycol mixes much more.
  • The values every 10 °C are handbook values and those at 5 °C, 15 °C and so on are interpolated between them (accuracy about 0.3 percent).

FAQ

What is the viscosity of water?

1.002 mPa·s (cP) dynamic and 1.004 mm²/s (cSt) kinematic at 20 °C. At 25 °C it is 0.890 mPa·s.

What is the kinematic viscosity of water in m²/s?

About 1.0 × 10⁻⁶ m²/s at 20 °C (1.004 × 10⁻⁶ m²/s), and 0.658 × 10⁻⁶ at 40 °C.

How does the viscosity of water change with temperature?

It falls roughly exponentially as the temperature rises, from 1.79 mPa·s at 0 °C to 0.28 mPa·s at 100 °C, a factor of more than six.

What is the difference between dynamic and kinematic viscosity?

Dynamic viscosity (μ) is the resistance to shear, in Pa·s or cP. Kinematic viscosity (ν) is μ divided by the density, in m²/s or cSt, and is the one used in the Reynolds number.

Sources

  • CRC Handbook of Chemistry and Physics, viscosity of water.
  • IAPWS release on the viscosity of ordinary water substance.
  • ASHRAE Handbook – Fundamentals, thermophysical properties of water.
  • Handbook values every 10 °C (CRC Handbook, IAPWS) for liquid water at about 1 atm; values at 5 °C, 15 °C and so on are interpolated (about 0.3 percent, following the exponential trend). Kinematic viscosity = dynamic viscosity ÷ density (Kell). 1 Pa·s = 0.671969 lb/ft·s; 1 m²/s = 10.7639 ft²/s.

Published by Nick Peterson, mechanical engineer.