Viscosity of Water vs Temperature (Dynamic and Kinematic)
Dynamic and kinematic viscosity of water from 0 to 100 °C in SI and US units, cP and cSt.
The viscosity of water at 20 °C is 1.002 mPa·s (1.002 centipoise, the dynamic viscosity) and 1.004 mm²/s (1.004 centistokes, the kinematic viscosity). It falls quickly as water warms: it is 1.79 mPa·s at 0 °C, 0.89 at 25 °C and 0.28 at 100 °C.
This table gives both viscosities every 5 °C in SI and US units. Dynamic viscosity (μ) is used for shear stress and pumping; kinematic viscosity (ν = μ ÷ ρ) goes into the Reynolds number.
The table
| Temperature (°C) | Temperature (°F) | Dynamic viscosity (mPa·s = cP) | Dynamic viscosity (Pa·s) | Dynamic viscosity (lb/ft·s) | Kinematic viscosity (mm²/s = cSt) | Kinematic viscosity (m²/s) | Kinematic viscosity (ft²/s) |
|---|---|---|---|---|---|---|---|
| 0 | 32 | 1.792 | 0.001792 | 0.0012042 | 1.7923 | 1.7923E-6 | 1.9292E-5 |
| 5 | 41 | 1.5232 | 0.0015232 | 0.0010236 | 1.5233 | 1.5233E-6 | 1.6396E-5 |
| 10 | 50 | 1.307 | 0.001307 | 0.0008783 | 1.3074 | 1.3074E-6 | 1.4073E-5 |
| 15 | 59 | 1.1382 | 0.0011382 | 0.0007649 | 1.1393 | 1.1393E-6 | 1.2263E-5 |
| 20 | 68 | 1.002 | 0.001002 | 0.0006733 | 1.0038 | 1.0038E-6 | 1.0805E-5 |
| 25 | 77 | 0.89 | 0.00089 | 0.000598 | 0.8926 | 8.926E-7 | 9.608E-6 |
| 30 | 86 | 0.797 | 0.000797 | 0.0005356 | 0.8005 | 8.005E-7 | 8.616E-6 |
| 35 | 95 | 0.7191 | 0.0007191 | 0.0004832 | 0.7234 | 7.234E-7 | 7.787E-6 |
| 40 | 104 | 0.653 | 0.000653 | 0.0004388 | 0.6581 | 6.581E-7 | 7.084E-6 |
| 45 | 113 | 0.5961 | 0.0005961 | 0.0004006 | 0.602 | 6.02E-7 | 6.48E-6 |
| 50 | 122 | 0.547 | 0.000547 | 0.0003676 | 0.5536 | 5.536E-7 | 5.959E-6 |
| 55 | 131 | 0.5044 | 0.0005044 | 0.0003389 | 0.5117 | 5.117E-7 | 5.508E-6 |
| 60 | 140 | 0.467 | 0.000467 | 0.0003138 | 0.475 | 4.75E-7 | 5.113E-6 |
| 65 | 149 | 0.4336 | 0.0004336 | 0.0002913 | 0.4422 | 4.422E-7 | 4.76E-6 |
| 70 | 158 | 0.404 | 0.000404 | 0.0002715 | 0.4132 | 4.132E-7 | 4.447E-6 |
| 75 | 167 | 0.3781 | 0.0003781 | 0.0002541 | 0.3879 | 3.879E-7 | 4.175E-6 |
| 80 | 176 | 0.355 | 0.000355 | 0.0002385 | 0.3653 | 3.653E-7 | 3.932E-6 |
| 85 | 185 | 0.334 | 0.000334 | 0.0002244 | 0.3448 | 3.448E-7 | 3.712E-6 |
| 90 | 194 | 0.315 | 0.000315 | 0.0002117 | 0.3263 | 3.263E-7 | 3.512E-6 |
| 95 | 203 | 0.2978 | 0.0002978 | 0.0002001 | 0.3096 | 3.096E-7 | 3.332E-6 |
| 100 | 212 | 0.282 | 0.000282 | 0.0001895 | 0.2943 | 2.943E-7 | 3.167E-6 |
Source and notes: Handbook values every 10 °C (CRC Handbook, IAPWS) for liquid water at about 1 atm; values at 5 °C, 15 °C and so on are interpolated (about 0.3 percent, following the exponential trend). Kinematic viscosity = dynamic viscosity ÷ density (Kell). 1 Pa·s = 0.671969 lb/ft·s; 1 m²/s = 10.7639 ft²/s.
How to use this table
- Find the water temperature and take the dynamic or kinematic viscosity in the units you want (cP and cSt are the common ones).
- The Reynolds number of a flow is Re = V D ÷ ν, with ν in m²/s: use the kinematic column.
- Convert: 1 mPa·s = 1 cP = 0.001 Pa·s; 1 mm²/s = 1 cSt = 10⁻⁶ m²/s.
Worked example: Reynolds number in a 50 mm pipe at 1.5 m/s
- At 20 °C the kinematic viscosity is 1.0038 mm²/s, so Re = 1.5 × 0.05 ÷ 1.0038×10⁻⁶ = 74,700 (turbulent).
- At 60 °C the viscosity is 0.4750 mm²/s, 2.11 times lower, so Re is 157,900: the same flow is 2.1 times more turbulent.
- Dynamic viscosity of 20 °C water: 1.002 mPa·s = 0.001002 Pa·s = 6.733×10⁻⁴ lb/(ft·s).
Notes and cautions
- Viscosity depends strongly on temperature: it halves between 20 and 50 °C. Use the viscosity at the working temperature of the fluid.
- Pressure has little effect on the viscosity of water at normal pressures (less than 1 percent per 100 bar).
- Seawater is about 8 percent more viscous than fresh water at the same temperature, and brines and glycol mixes much more.
- The values every 10 °C are handbook values and those at 5 °C, 15 °C and so on are interpolated between them (accuracy about 0.3 percent).
Related tools and guides
- Density of Water vs Temperature
- Specific Heat of Water vs Temperature
- Vapor Pressure of Water vs Temperature
- Boiling Point of Water vs Pressure and Altitude
- Water Properties vs Temperature
- Reynolds Number Calculator
- Pipe Flow and Pressure Drop Calculator
- All reference tables
FAQ
What is the viscosity of water?
1.002 mPa·s (cP) dynamic and 1.004 mm²/s (cSt) kinematic at 20 °C. At 25 °C it is 0.890 mPa·s.
What is the kinematic viscosity of water in m²/s?
About 1.0 × 10⁻⁶ m²/s at 20 °C (1.004 × 10⁻⁶ m²/s), and 0.658 × 10⁻⁶ at 40 °C.
How does the viscosity of water change with temperature?
It falls roughly exponentially as the temperature rises, from 1.79 mPa·s at 0 °C to 0.28 mPa·s at 100 °C, a factor of more than six.
What is the difference between dynamic and kinematic viscosity?
Dynamic viscosity (μ) is the resistance to shear, in Pa·s or cP. Kinematic viscosity (ν) is μ divided by the density, in m²/s or cSt, and is the one used in the Reynolds number.
Sources
- CRC Handbook of Chemistry and Physics, viscosity of water.
- IAPWS release on the viscosity of ordinary water substance.
- ASHRAE Handbook – Fundamentals, thermophysical properties of water.
- Handbook values every 10 °C (CRC Handbook, IAPWS) for liquid water at about 1 atm; values at 5 °C, 15 °C and so on are interpolated (about 0.3 percent, following the exponential trend). Kinematic viscosity = dynamic viscosity ÷ density (Kell). 1 Pa·s = 0.671969 lb/ft·s; 1 m²/s = 10.7639 ft²/s.