Vapor Pressure of Water vs Temperature (Saturation Pressure)
Saturation pressure of water from 0 to 200 °C in kPa, bar, psia, atm, mmHg and inHg.
The vapor pressure of water (its saturation pressure) is 2.34 kPa at 20 °C, 12.35 kPa at 50 °C and 101.4 kPa at 100 °C. Water boils when its vapor pressure equals the pressure around it, which is why it boils at 100 °C at sea level. Vapor pressure rises very steeply with temperature.
This table gives the saturation pressure from 0 to 200 °C in kPa, bar, psia, atm, mmHg and inHg. It is the table to use for pump suction (NPSH), vacuum and evaporation, and for the water vapor in humid air.
The table
| Temperature (°C) | Temperature (°F) | Vapor pressure (kPa abs) | Vapor pressure (bar abs) | Vapor pressure (psia) | Vapor pressure (atm) | Vapor pressure (mmHg) | Vapor pressure (inHg) |
|---|---|---|---|---|---|---|---|
| 0 | 32 | 0.6112 | 0.00611 | 0.0886 | 0.00603 | 4.584 | 0.18 |
| 5 | 41 | 0.8725 | 0.00872 | 0.1265 | 0.00861 | 6.544 | 0.258 |
| 10 | 50 | 1.228 | 0.01228 | 0.1781 | 0.01212 | 9.211 | 0.363 |
| 15 | 59 | 1.7054 | 0.01705 | 0.2474 | 0.01683 | 12.792 | 0.504 |
| 20 | 68 | 2.3388 | 0.02339 | 0.3392 | 0.02308 | 17.542 | 0.691 |
| 25 | 77 | 3.1692 | 0.03169 | 0.4597 | 0.03128 | 23.771 | 0.936 |
| 30 | 86 | 4.246 | 0.04246 | 0.6158 | 0.04191 | 31.848 | 1.254 |
| 35 | 95 | 5.6278 | 0.05628 | 0.8162 | 0.05554 | 42.212 | 1.662 |
| 40 | 104 | 7.3835 | 0.07383 | 1.0709 | 0.07287 | 55.381 | 2.18 |
| 45 | 113 | 9.5932 | 0.09593 | 1.3914 | 0.09468 | 71.955 | 2.833 |
| 50 | 122 | 12.3499 | 0.1235 | 1.7912 | 0.12188 | 92.632 | 3.647 |
| 55 | 131 | 15.7597 | 0.1576 | 2.2858 | 0.15554 | 118.208 | 4.654 |
| 60 | 140 | 19.9438 | 0.19944 | 2.8926 | 0.19683 | 149.591 | 5.889 |
| 65 | 149 | 25.0387 | 0.25039 | 3.6316 | 0.24711 | 187.806 | 7.394 |
| 70 | 158 | 31.1979 | 0.31198 | 4.5249 | 0.3079 | 234.004 | 9.213 |
| 75 | 167 | 38.5924 | 0.38592 | 5.5973 | 0.38088 | 289.467 | 11.396 |
| 80 | 176 | 47.4116 | 0.47412 | 6.8765 | 0.46792 | 355.616 | 14.001 |
| 85 | 185 | 57.8645 | 0.57865 | 8.3925 | 0.57108 | 434.02 | 17.087 |
| 90 | 194 | 70.18 | 0.7018 | 10.1788 | 0.69262 | 526.394 | 20.724 |
| 95 | 203 | 84.6078 | 0.84608 | 12.2713 | 0.83501 | 634.611 | 24.985 |
| 100 | 212 | 101.419 | 1.01419 | 14.7095 | 1.00092 | 760.703 | 29.949 |
| 110 | 230 | 143.384 | 1.43384 | 20.796 | 1.41509 | 1075.47 | 42.341 |
| 120 | 248 | 198.685 | 1.98685 | 28.8168 | 1.96087 | 1490.26 | 58.672 |
| 130 | 266 | 270.298 | 2.70298 | 39.2034 | 2.66763 | 2027.4 | 79.819 |
| 140 | 284 | 361.565 | 3.61565 | 52.4406 | 3.56837 | 2711.96 | 106.77 |
| 150 | 302 | 476.198 | 4.76198 | 69.0667 | 4.69971 | 3571.78 | 140.621 |
| 160 | 320 | 618.275 | 6.18275 | 89.6732 | 6.1019 | 4637.45 | 182.577 |
| 170 | 338 | 792.235 | 7.92235 | 114.904 | 7.81875 | 5942.25 | 233.947 |
| 180 | 356 | 1002.87 | 10.0287 | 145.454 | 9.89757 | 7522.16 | 296.148 |
| 190 | 374 | 1255.32 | 12.5532 | 182.069 | 12.3891 | 9415.71 | 370.697 |
| 200 | 392 | 1555.07 | 15.5507 | 225.544 | 15.3474 | 11664 | 459.213 |
Source and notes: Hyland, R. W. and Wexler, A., Formulations for the thermodynamic properties of the saturated phases of H2O, ASHRAE Transactions 89(2A), 1983 (0 to 200 °C); agrees with the IAPWS steam tables to better than 0.1 percent. 1 mmHg = 133.322 Pa, 1 inHg = 3386.389 Pa.
How to use this table
- Find the temperature of the water (or of the surface) and read the saturation pressure in your pressure unit. These are absolute pressures.
- Water boils when the pressure over it drops to this value: a pump suction below the vapor pressure causes cavitation.
- In humid air the partial pressure of water vapor at saturation is the same value; relative humidity = vapor pressure ÷ saturation pressure.
Worked example: pump taking 70 °C water from an open tank at sea level
- At 70 °C the vapor pressure is 31.20 kPa abs (4.52 psia), and the density of the water is 977.8 kg/m³.
- The pressure head available above the vapor pressure is (101.325 − 31.20) kPa ÷ (ρ g) = 7.31 m.
- With the water level 2 m above the pump and 0.5 m of suction pipe loss, NPSH available = 7.31 + 2 − 0.5 = 8.81 m. This must exceed the pump’s NPSH required, with a margin.
Notes and cautions
- Vapor pressure grows by a factor of about 5 between 20 and 50 °C and by about 8 more by 100 °C, which is why hot water is hard to pump without cavitation.
- Values are absolute pressures in the unit shown (kPa abs, psia, bar abs). Subtract atmospheric pressure to get a gauge pressure.
- The equation used (Hyland–Wexler) is for pure water against a flat surface; dissolved salts lower it slightly (Raoult’s law) and small droplets raise it.
- The last rows go to 200 °C, where water at 1.55 MPa is the boiling liquid in a steam boiler.
Related tools and guides
- Density of Water vs Temperature
- Specific Heat of Water vs Temperature
- Viscosity of Water vs Temperature
- Boiling Point of Water vs Pressure and Altitude
- Water Properties vs Temperature
- Dew Point Calculator
- Pump Power and Sizing Calculator
- Psychrometric Calculator and Chart
- All reference tables
FAQ
What is the vapor pressure of water at 100 °C?
101.4 kPa (14.7 psia, 1 atm), equal to the normal atmospheric pressure, which is why water boils at 100 °C at sea level.
What is the vapor pressure of water at 25 °C?
3.17 kPa (0.46 psia, 23.8 mmHg).
What is the vapor pressure of water at 20 °C?
2.34 kPa (17.5 mmHg, 0.34 psia), about 2.3 percent of an atmosphere.
What is saturation pressure?
The pressure at which a liquid and its vapor are in equilibrium at a given temperature. For water it is another name for the vapor pressure.
Sources
- Hyland, R. W. and Wexler, A., Formulations for the thermodynamic properties of the saturated phases of H₂O from 173.15 K to 473.15 K, ASHRAE Transactions 89(2A), 1983.
- IAPWS-IF97 steam tables for comparison.
- Hyland, R. W. and Wexler, A., Formulations for the thermodynamic properties of the saturated phases of H2O, ASHRAE Transactions 89(2A), 1983 (0 to 200 °C); agrees with the IAPWS steam tables to better than 0.1 percent. 1 mmHg = 133.322 Pa, 1 inHg = 3386.389 Pa.